Distributor High Efficiency 6 ton gas boiler Philippines

It is reported, is located in Changji City, Xinjiang Uygur Autonomous Region is determined to win the battle pollution prevention and control, through the implementation of coal-fired distributor high efficiency 6 ton boiler philippiness, industrial control mentioned standard, smoke dust pollution control and many other initiatives, the quality of atmospheric environment sustained and steady improvement.

This year, Changji City will continue to improve the environmental quality at the core, out to win tough fight pollution prevention, environmental protection take interviews, special inspection, etc., to strictly implement the main responsibility for environmental protection and various functional units of the company, continued to carry out inspection of law enforcement to crack down on various types of environmental violations. Intensify its efforts in the "coal to gas", "coal to electricity" and other aspects, has in the Town of sulfur heating station implemented the "coal to electricity" project, Onishi canal Heng Xin heat, car city, nine branch offices, Yihai Oil company implemented a central heating alternative project, blue mountains Tunhe polyester company implemented the "coal to gas" project. With the implementation of a key environmental projects and put into use, the construction of sky blue, green, clear water of "clean Changji," the grand blueprint is becoming a reality.

Four coal-fired distributor high efficiency 6 ton boiler philippiness precautions to meet a variety of fossil fuels and natural gas sectors of production, often require boiler, the general common is to transform into a coal-fired furnace gas-fired boiler, to change the high fuel costs of coal on the environment cause serious pollution problems, specific issues unique boiler is not a small project, you need to pay attention to a good close links with each transformation in order to avoid failure of transformation, on boiler should be noted that we have to understand the following description. 1, the original boiler demolition work; boiler before carrying out the original host and auxiliary boilers need to be demolished, concrete demolition work carried out by professional staff, in order to more quickly complete the demolition work with but also to prevent the demolition process in the event of any accident; 2, note that pressure capacity of the boiler; small boiler into the gas by the coal-fired, also changed the original negative and positive pressure combustion burner, the process you need to pay special attention throughout the furnace wall the structure and sealing, the sealing function, it might cause the boiler after the transformation could not withstand the pressure and accidents; 3, furnace renovation precautions; when in many cases will change the gas burner, because the fuel mist of poor or incomplete combustion of the fuel gas remaining in the furnace a little mistake will cause fire or explosion, it is carried out after completion of the transformation for an explosion vent installed in an appropriate position to prevent the explosion, while additional ignition flame protection means after the boiler guarantee safe operation; 4, after the transformation of the test; after the completion of high-quality boiler transformation, but also the need for reuse Sophisticated testing to confirm their safety, commonly used test method is boiler pressure after the transformation of high-pressure test, and finally pass a test meet the standard may be considered completed after the entire transformation boilers. Caution visible through major transformation over the course of gas boilers, boiler reconstruction requires not only technical but also need to meet the relevant standards in order to ensure more successful boiler and can be smoothly carried out using, of course, in the transformation of the former users need to analyze the structure of the entire boiler study, confirming boiler renovation project can be re-introduced in order to avoid unnecessary waste.

You must know the distributor high efficiency 6 ton boiler philippines energy problems (induced draft fan power consumption rate, steam consumption) draft fan causes problems 1.1 boiler flue dust and fouling, in particular air preheater fouling, resulting in increased resistance to smoke duct . 1.2 boiler flue, tail heating surface and dust leakage. 1.3 Leakage Rate large air preheater. 1.4 furnace excess air coefficient is too large. 1.5 unit load changes, run the adjustment is not timely, resulting in furnace pressure is too large. 1.6 unit load or low frequent starts and stops. 1.7 coal into the furnace worse, from the design value. 1.8 low efficiency filter. 1.9 draft fan blade badly worn, low operating efficiency. 1.10 fan outlet flue gas desulfurization big resistance. 1.11 soda boiler pipes for leaks. 2, 2.1 to 2.1.1 operational measures to solve the problem of the strict implementation of soot blowing system to prevent the heated area ash, blocking ash, flue gas system to reduce resistance. 2.1.2 holding the induced draft fan, the flue gas separator baffles and dampers in the fully open position. 2.1.3 The experiment showed combustion boiler, proper control of excess air in the furnace. 2.1.4 adjustment chamber negative pressure, air leakage reduction furnace and the flue. 2.2 routine maintenance and testing 2.2.1 induced draft fan performance test to determine the optimum operating point and efficient workspace. 2.2.2 boiler, air preheater, a flue, ESP and other system leakage inspection, process. 2.2.3 timely check processing chassis, shaft seal leakage. 2.3C / D repair, eliminating defects 2.3.1 down strict accordance with movement clearance adjusting fan. 2.3.2 induced draft fan blade defect action elimination hand vane opening adjustment. 2.3.3 Importers and induced draft fan baffle opening check. 2.3.4 duct tightness check process. 2.3.5 wave plate replacement air preheater, rinsed sector plate gap adjustment. 2.3.6 eliminate dust defects and improve collection efficiency. 2.3.7 clean flue gas desulfurization system, flue resistance is reduced. 2.3.8 eliminate soda boiler pipe leakage defects. 2.4A / B repair and transformation 2.4.1 Check and repair the fan blades, replace seriously damaged blades if necessary. 2.4.2 for energy saving fan efficiency below 75%. 2.4.3 The fan motor frequency transformation. 2.4.4 of the precipitator, if necessary, transform and improve collection efficiency.

Low nitrogen distributor high efficiency 6 ton boiler philippines and classification of meaning: In recent years, the state vigorously promote clean air plan, Yajian coal. Whether the use of coal-fired central heating boilers, and rural small coal stove for cooking and heating, are gradually being clean energy alternatives under the relevant policy. Thus, in recent years, sulfur dioxide, dust content in the atmosphere continues to decline. But it is worth noting that more and more use of natural gas, also caused a certain amount of nitrogen oxide pollution. Use low nitrogen boiler of the environmental benefits of very large.