8t Natural Gas steam boiler Agent Singapore

Our hotel attaches great importance to environmental protection philosophy, always bear in mind the protection of environmental quality in Xiamen. Therefore, we chose to stay ahead of the fast boiler industry cooperation in clean and green boiler, electric 8t steam boiler agent singapores party fast to ensure that we provide the normal work requirements at the same time, has a very clear environmental performance. --customer feedback

Gas-fired 8t steam boiler agent singapore plant accident management system, equipment or components of the gas steam boiler damage due to abnormal loss of accuracy, reach the level of accidents is the equipment failure. 2. The main gas steam boiler equipment failure rate evaluation, the failure rate under 23%. 3, less maintenance costs of a gas steam boiler of a device for the 500≤1000 yuan. Gas hot water boiler with environmental protection, energy conservation, safety, salient features fully automatic operation, and ease of use. In addition, due to the operation of the economy, government policies to encourage, gas hot water boiler more and more people of all ages. Steam boiler is an energy conversion device, the energy input to the boiler fuel chemical energy, electrical energy, thermal energy and other forms of high temperature flue gas, and after converting the boiler, the steam output having a certain outside thermal energy, high-temperature hot water or an organic carrier. Small, large, thin device 1000≤ membered or power outages caused by equipment failure company 10 minutes 30 minutes belong to ordinary accident. 4. Gas-fired steam boiler single piece of equipment maintenance costs more than 10,000 yuan, fine, big, thin device more than 30,000 yuan, or due to an accident caused power outages company for more than 30 minutes. The single gas steam boiler equipment maintenance costs more than 500,000 yuan, or accident due to equipment being shut down more than two days, shut down more than a week. Biomass boiler categories: biomass boilers Horizontal, vertical biomass boilers. Biomass gas thermal oil heaters, biomass steam boiler, biomass hot water boiler, biomass oil furnace. 6. Gas-fired steam boiler equipment accident occurs, stop immediately and on-site maintenance. Operator shall immediately report to the workshop, the workshop should be reported immediately to the production department, production department shall, jointly with relevant departments to seriously inspect the site. Responsibility to identify and deal with. When major or serious accident, the production department should ensure quality engineer reported within two hours. 7. Gas-fired steam boiler equipment accidents occur, three things must adhere to the principle of letting go (ie the cause of the accident is unknown, the responsibility for the accident and the masses have no education, no preventive measures), identify the causes and responsibilities, based on the circumstances giving administrative sanctions or financial compensation to punish people break the law according to the law.

Boiler fire phenomenon, how to do 1, furnace pressure fluctuations or to limit and alarm. 2, no flame detector flame, flame flameless television display. 3, flue gas oxygen abnormal fluctuations. 4, steam pressure steam temperature dropped drastically. 5, furnace black, black smoke chimney. 6, the flue gas temperature is reduced. 7, MFT action, turbine trip, splitting the unit. Cause 1, the furnace combustion conditions organizations unreasonable, improper wind coal proportion. 2, the load is too low, unstable combustion conditions without oil combustion vote, or vote, although oil but not good combustion results. 3, cast oil, poor quality oil, oil spray gun is bad, low oil pressure, oil system failure. 4, poor coal quality, coal is too rough, the water is too large pulverized coal combustion adjustment is not timely. 5, the primary air temperature, air pressure is too low. 6, boiler MFT protection action. 7, a large area of ​​the furnace coke collapse, smashing off the flame. 8, severe water wall pipe explosion will blow out the flame. 9, all coal-fired condition, mill pulverizing system failure caused most or all trips. 10, a part of auxiliary machinery such as a fan, blower, fan, air preheater tripped, causing unstable furnace combustion conditions. 11, sootblowing properly, resulting in a large number of normal operation of the furnace ash effects of fire inspection of the boiler. 12, bottom seal damage. Treatment 1, the boiler fire, MFT should be action, otherwise manual MFT. 2, normal inspection device linkage linkage MFT, confirm that all fuel cut. 3. quickly identify the cause, try to eliminate the boiler can be re-ignition, the recovery unit operation. 4, when the mill started again after the trip, the trip must be the primary air tube mill full purge. 5, the MFT operation, checks, Fan normal operation, automatic furnace vent. 6, the MFT movement, check all the secondary purge air damper position is set, the total air volume is automatically adjusted to 30 ~ 40% BMCR sufficiently purged air volume. 7, the MFT operation, when the turbine is in a state disk drive, the disk drive must continue until the normal turbine eccentricity, before re turn red. 8, if temporarily unable to identify or eliminate the cause, restart and could threaten personal safety equipment, non-start. 9, processing according to the corresponding predetermined remaining MFT.

What are the overall structure of the boiler boiler structure includes two major boiler and auxiliary equipment. Boiler furnace, drum, burner, water wall superheater, economizer, air preheater, and the furnace wall, etc. The main frame member constituting the core part of the steam production, called boiler. Boiler body is in two main parts and drum furnace. Also known as the furnace combustion chamber, fuel combustion for space. The solid fuel on to the grate, referred to as a fire bed combustion furnace Stoker, also known as fire bed furnace; solid fuel furnace liquid, gas or pulverized, is injected into the combustion chamber is called the fire chamber burner, also known as the furnace fire chamber; air coal particles burn hold it was boiling, and the furnace is inferior fuel suitable for combustion is called fluidized bed furnace, also called fluidized bed furnace; coal particles so that an air flow rotated at high speed, and strongly called fire cylindrical cyclone furnace hearth. The furnace cross-section is generally square or rectangular. Combustion fuel to form a flame in the furnace and high temperature flue gas, so the hearth around the furnace wall is made of refractory material and insulation material. On the inner surface of the wall of the furnace waterwall tubes often laid, it will not burn both protect the furnace wall, and absorb a large amount of radiation heat of the flame and the high temperature flue gas. Furnace design needs to fully consider the characteristics of the fuel used. Each boiler should be fueled with the original design of the fuel. Boilers running economy and reliability are likely to vary greatly reduced when using the characteristics of fuel combustion. And the natural circulation drum is repeatedly forced circulation boiler receiving feedwater to the economizer, the coupling cycle and supplying saturated steam superheater cylindrical vessel. Simplified drum made from high quality steel plate, is one of the heaviest components of the boiler. The main function of the water storage drum, a steam separator, brine and water excluded pot sludge in operation, to avoid the boiler water containing a high concentration of salt and impurities entering with the steam superheater and a steam turbine. Internal drum means comprises a moisture separator and a steam cleaning apparatus, water distribution pipes, sewage and dosing equipment. Wherein the effect of soda is separated from the water wall by means of saturated steam and water to leave, and to minimize the steam carried fine water droplets. Low pressure boiler used as a crude flap and slit baffle separating element; above except pressure in the boiler is widely used for various types of rough separation cyclone, but also with blinds, steel mesh plate or the like are vapor further separation. The drum is also equipped with water gauges, safety valves and other monitoring and protection facilities. In order to improve the design and performance assessment, often have to go through boiler thermal balance test. Direct methods to calculate the thermal efficiency of the boiler is called n-efficient use of energy balance, the heat loss from a variety of methods to counter the counter balance called computational efficiency. When considering the practical benefits of the boiler room, boiler thermal efficiency not only look, but also taking into account the energy consumed by the auxiliary boiler. Fuel per unit mass or unit volume of complete combustion, calculated according to the chemical reaction called the theoretical air quantity of air required. In order to have more opportunities to the fuel in contact with oxygen in the furnace combustion, the actual amount of air into the furnace is always greater than the theoretical air amount. While air can be reduced into a multi incomplete combustion heat loss, but the heat losses will increase, also exacerbate corrosion of sulfur oxides and nitrogen oxides generated. We should therefore seek to improve combustion technology, as small as possible in order for the excess air ratio in the furnace so that complete combustion. Dust contained in the boiler flue gas (including carbon black and ash), sulfur and nitrogen oxides are air pollutants, which can achieve emissions targets environmental regulations when unpurified indicators several to several tens of times. These substances emissions control combustion pretreatment, improved combustion techniques, dust removal, desulfurization and denitration. By means of a high chimney stack can reduce the concentration of pollutants in the atmosphere of the area. Flue gas dust removal force used gravity, centrifugal force, inertial force and acoustic adhesion, static electricity and the like. Is generally used for separating coarse particles gravity settling and inertial force, centrifugal separation is often used dust bag filters and electrostatic precipitators having a high dust removal efficiency at higher capacity. Wet venturi - water film adhering water film droplet precipitator ash, high collection efficiency can absorb gaseous pollutants. Since the 1950s, people strive to develop the comprehensive utilization of ash, harm into. The manufacturing cement, bricks and building materials such as concrete aggregate ash. Since the 1970s and from the fly ash cenospheres extracted as a fire-resistant insulation and other materials. Future development will further improve boiler thermal efficiency of boilers and power plants; reduce equipment cost per unit of power boilers and power plants; enhance operational flexibility and level of automation of the boiler unit; develop more varieties to suit different boiler fuel; and improve boiler unit the reliability of operation of the auxiliary equipment; reduce environmental pollution.