horizontal diesel oil fired water tube boiler

The safety inspection operations will be based on "regarding the development of horizontal diesel fired water tube boilers and industrial emergency notification equipment and facilities safety inspection of" (Wei Safety Office Zi [2019] No. 23) documentation requirements, earnestly implement the regulatory responsibility, and actively carry out arrangements, combined with Cravens practical, clear pressure boiler safety inspection work content and division of tasks.

In conjunction with the National Health City welcome the review investigation work, based on their job functions, all members of the team to take the sinking line, full package by, Division linkage approach, focusing on whether the boiler to handle the use of registration, whether periodic inspection, workers who whether induction certificate, the safety valves and pressure gauges and other safety accessories boilers are using the site regularly check verification, the highest level gauge whether there has been a minimum level of safety markings for verification. 54 boiler region's 24 units were one by one investigation. Up to now, all 33 units in the boiler are in an examination period, in line with the requirements. It has two boilers to handle the deregistration, and 19 boilers have long-term disabled, is now urging the use of units to seize deregistered.

While actively step up publicity and training efforts, and send more professionals to communities, cooperatives were the main person in charge of safety knowledge of professional training, to explain the basics of boiler and check focus, effective universal safety knowledge, improve regulatory efficiency.

Steam horizontal diesel fired water tube boiler pressure controller function and debugging methods fired boiler, gas-fired boiler, steam boiler pressure controller and debugging method acting pressure controller is a pressure signal into an electric signal electromechanical conversion device, its function will be the high pressure or low levels of The electrical switching signal to the external circuit for automatic control or chain protection. Common pressure controller and pressure gauge, vapor pressure overpressure alarm can cut off the burner limit is reached; pressure controller adjusts single fire or dual fire burning the actual operating pressure; for large burner, the pressure may be adjusted according to the size of the size of the oil / gas, and always keep the pressure stable operation. Currently electrical contacts have been rarely used. Above the boiler pressure controller typically uses steam boiler pressure controller are used two to three pressure controller. Wherein a start and stop control furnace, for controlling a large and small fire conversion, there is used an overpressure protection. Two start and stop the boiler pressure controller is generally used to control the temperature controller, pressure controller is arranged to control the two-position and fire the boiler overpressure protection. Three safety accessories on the boiler must be in accordance with the procedures set two, which is intended primarily for safety. First, you can work to prevent another when one of them fails. Second, the purpose of comparison, in particular water level gauge and a pressure controller, to ensure safety, the operator to observe only one of which is the value indicated, but also controls the display shown two values ​​match. 3 generally require a pressure controller, operation is as follows: the first is a power adjusting; e.g. a small fire is set 0.5MPa, 0.4MPa furnace start, the adjustable screw -difference pressure controller (hysteresis) is 1, range (set value) is set to 5. The second pressure is shutdown, diffe set to minimum, range adjusted to 6 (0.6MPa). The third overpressure alarm is set at about 0.7Mpa. Note: the pressure differential must first be transferred back controller adjustment process, and then transferred range. Gas steam boiler pressure controller debugging, generally follow the principle: high pressure, is used as the overpressure protection; high pressure, as boiler start-stop control; low pressure, as a large and a small fire conversion. Specific pressure range may be adjusted according to the nominal pressure boilers and the requirements of use.

The szs series and wns series of oil and gas horizontal diesel fired water tube boilers produced by ZG boiler are the most widely used. In a big way, it can be widely used in heating, industrial steam and hot water supply, and the company has its own power station. Such as school heating, hotel bath hot water supply, food factory industrial steam supply. These two oil and gas boilers are all fast-assembling boilers with low capital investment and high degree of automation. Customers can choose according to their needs.

Boiler is a very common equipment used for heating, heating and bathing. In many industries, it is inseparable from the use of industrial steam horizontal diesel fired water tube boilers and hot water boilers. But we need to recognize that boilers exacerbate pollution problems. As an important pollutant of PM2.5, NOx has become the top priority of air pollution control. Many countries and regions have limited the emission of boiler air pollutants according to local conditions and development status. The low-nitrogen condensing oil and gas boiler produced by ZG boiler uses a number of low-nitrogen technologies with NOx emissions as low as 26 mg/m3.