condenser 2t hr gas steam boiler

To introduce condenser 2t hr steam boiler pressure gauge and hydraulic press accumulator using steam boiler pressure gauge should pay attention to: 1, rated steam pressure is less than 2.45MPa steam boiler, the accuracy of pressure gauge must not be 2. 5; Rated steam pressure large or equal to 2.45MPa boiler, pressure must not be less than 1. 5 class. The diameter of the dial of the pressure gauge shall not be less than 100 mm to ensure that the operator can see clearly the surface pressure indicator value. 2. A red line should be drawn on the pressure dial of the steam boiler pressure gauge, indicating the maximum allowable working pressure. Steam boiler pressure gauges should be installed in a place that is easy to observe and wash. 4. Steam boiler pressure gauges should be checked at least once every six months, and should be sealed with lead after calibration. 5. Steam boiler pressure gauges should not have leakage of water and steam leakage in the connecting tubes of the pressure gauges of steam boilers. (4) the steam boiler pressure gauges should be checked at least once every six months and sealed with lead. 5. Otherwise, the pressure indicator value will be reduced. 6. The measurement range of the steam boiler pressure gauge should be adapted to the working pressure of the measured components, usually 1.5 times of the working pressure, preferably 2 times of the working pressure. Steam boiler does not have pressure gauge, the pressure gauge is damaged or the installation of pressure gauge does not meet the requirements, steam boiler pressure gauge should be stopped when one of the following conditions: 1, broken surface glass or dial calibration mold There is no clear paste; 2, no lead seal, lead seal damage or beyond the calibration period; 3, without pressure, the pressure gauge of the finite pin can not be restored to the limit pin, the infinite position of the gauge pointer deviated from zero data beyond the allowable pressure clothing; 4, gas leakage or pointer jump in the meter; 5, other defects that affect the accuracy of the gauge. Purpose of the accumulator: the accumulator is used in the hydraulic system of intermittent machinery, which stores the oil output of the hydraulic pump during intermittent or low-speed movement of the actuator, and when the rapid movement of the actuator requires a large flow rate, As an auxiliary energy source, together with the hydraulic pump, the oil pump is supplied to the system, thus the oil pump and the hydraulic pump are realized. The miniaturization of the whole hydraulic device absorbs the quick opening and closing of the impact hydraulic reversing valve and the sudden change of the load. The system will produce shock pressure, the darling will lead to vibration and noise, and even damage the machine. The accumulator can mitigate the impact pressure absorption pulsation of these fluids absorb and reduce the flow pulsation and pressure pulsation of various hydraulic pumps thus reducing the system noise and vibration. The damped accumulator acts as a gas spring and can be used to absorb the vibration between the fuselage and wheels of walking machinery such as vehicles. The balanced accumulator absorbs the gravitational potential energy of the vertical actuator (hydraulic cylinder) and its load as it falls. When the vertical actuator rises, the accumulator releases the original absorbed energy and supplies oil to the hydraulic cylinder together with the pump, thus realizing the balance and energy saving.

Inside the Fangkuai boiler plant, there is a special corrugated furnace bladder production line, which can be processed according to the computer setting mode. At the same time, this is also a unique processing technology of Fangkuai Boiler. The cost of natural gas fuel alone exceeds 5 million yuan per year. The corrugated furnace liner fired by this production line can not only increase the heating surface of the boiler, but also alleviate the damage caused by the thermal expansion and contraction to the combustion chamber, and greatly extend the service life of the boiler.

(Iii) use of a waste heat boiler for heat recovery. Using the waste heat boiler using waste heat discharged from the heat of the flue gas in a boiler to heat water or generate steam. Such waste heat boiler is provided thermal oil furnace itself does not change the fuel consumption, the waste heat boiler to produce steam or hot water may be used for the production and the occurrence of heating, thereby indirectly ADSF fuel savings. A waste heat boiler provided the following effects: First, since the heat recovery water, it is easy to improve the thermal efficiency of the furnace. Second, because the number of boiler flue gas can be centralized heat recovery, thereby reducing the cost of construction of the heat recovery unit.

Note matters including gas boiler gas water boiler, gas hot water boiler, gas condenser 2t hr steam boiler operation gas boiler, gas hot water boiler which is also known as gas heating boilers and gas boilers bath, as the name suggests refers to the gas boiler fuel gas boilers, gas boilers and oil-fired boiler, electric boiler compared to the most economical, most people have opted for a gas boiler as steam, heating, boiler equipment for bathing. Note that the operation of the gas boiler gas boiler valve matter is very common to use an apparatus of the plant, under normal circumstances the handle, thorium clockwise rotation of the handwheel is turned off a predetermined direction, the rotation is defined as counterclockwise opening direction. But before the operation should focus on some check valve opening and closing flag after the operation. The following gas boiler manufacturers of small series simply to introduce the next gas boiler ajar fast opening valve operation Note: gas boiler slowly open the valve to open, slightly open after the quick opening valve, preheat the pipe and then fully open. For better results the sewage, can switch several quick open valve. After discharge, turn off the quick opening valve, then slowly open the valve is closed, and finally open about fast opening valve between two valves to put water in the net.