Supplier Commercial 4t Natural Gas hot water boiler

By the end of 2018, Wu'an Municipal People's Government of Hebei Province issued a notice on the issuance of "blue sky Wu'an winning three-year action plan to defend the war", referring to the notification: By the end of 2019, the city has a depth of discharge conditions for reconstruction the coal-fired units completed in-depth treatment, meet the relevant standards. Implementation of coal-fired power management depth. Implementation of coal-fired power plants and coal-fired units emission performance management, emissions of coal-fired units to assess the performance rankings, and resolutely out of shutting down environmental protection, energy consumption, security is not up to 300,000 ten million coal-fired units.

First, the implementation of in-depth treatment of coal-fired power plant

Implementation of coal-fired power plants and coal-fired units emission performance management, emissions of coal-fired units to assess the performance rankings, and resolutely out of shutting down environmental protection, energy consumption, safety and other 300,000 kilowatts coal-fired units of non-compliance. 2018, 2019, 2020, respectively, by province and Handan given task given the amount of closed down. Heating demand complete transformation of 600,000 kilowatts grade pure condensing units, high-capacity, high-parameter units accounting for 90%

on.

Special action to carry out deeper cuts power industry, coal-fired units in the original ultra-low emissions, based on the further optimization of operational management, improve pollution control facilities, improving removal efficiency, the implementation of colored smoke plume power plant management. Before the end of 2019, the city has deeper emission coal-fired units to complete the transformation of the conditions of the depth of management, meet the relevant standards.

Second, to carry out special treatment industrial furnaces

The development of industrial furnaces comprehensive remediation plan to carry out an intensive investigation of industrial furnaces, establish classification list management. Stringent emission standards, increase efforts to eliminate non-compliance of industrial furnaces, accelerate the elimination of small and medium gas furnace. Under the premise of resources to implement and encourage industrial furnaces use electricity, natural gas and other clean energy or heat from the surrounding power plant. Ban coal stove, substantially eliminated cogeneration heating pipe network coverage in the range of coal heated oven (furnace); out hearth diameter of 3 m or less gas furnace fuels, natural gas use conditions have temporarily , building a unified center of clean coal gas principle; prohibition blended with high-sulfur petroleum coke.

Natural gas boiler once a day to check how long it takes much time to check the gas boiler natural gas boiler includes a gas water boiler, gas supplier commercial 4t hot water boiler, gas steam boilers, gas hot water boiler which is also known as gas heating boilers and gas boilers bath , gas boilers name suggests refers to the fuel gas boilers, gas boilers and oil-fired boiler, electric boiler compared to the most economical, most people have opted for a gas boiler as steam, heating, boiler equipment for bathing. According to market surveys, gas boilers and coal-fired boilers scheduled inspection time, like once a year, April 19, 2018, the special prosecutor in Daxing District in Beijing Yizhuang three sheep, six 68MW heating Limited (approximately equal to 40T) of gas heating boiler regular inspections. On-site inspectors checked the calendar year of inspection reports, operating records, factory data boiler, the operator asked in detail about the boiler operating conditions during the winter heating, internal inspection carried out in accordance with these four boiler inspection program. Focus on examination of water tube boilers, membrane wall inside the furnace tubes, burners, fire insulation materials, while making inspection records.

Preparation and method for measuring the moisture content of the flue gas of the boiler before the boiler purchase this product knowledge and understanding, the present, it is necessary for two reasons, first, it is the site of important product and the main key one word, and second, the products are widely used, why we have these conclusions and specific requirements. Meanwhile, I hope that we can be taken seriously and, in order to have learned well and apply their knowledge to practical work flexibly. Is there some preparatory work before the boiler 1. buy? Boiler products to buy, this is an important job, and need to be taken seriously, but also want to take into account all relevant factors, in order to have accurate judgments and the correct choice, a good choice to avoid mistakes. Before carrying out this work, is the need to do some preparation, use of the product to the environment and have a clear understanding of the requirements and learn about product origin, specifications, technical parameters, materials, quality, price, service and product manufacturers these and other basic information, in order to compare and consider, then, the right to choose their own products. 2. whether Sheung Shui before the boiler starts have specific requirements? From a professional point of view, Sheung Shui before the boiler starts, there are some basic requirements, which specifically is: If the supplier commercial 4t hot water boiler, the water speed before it starts not too fast, not be less than the winter time Sheung Shui 4 hours, in other seasons upper water time of not less than 2-3 hours. And, at the beginning of the water, its water speed to slow. If the boiler is cold, it's inlet temperature in the range of 50 ℃ -90 ℃, and the difference between the water temperature and the temperature of the drum wall into the steam drum, not greater than 40 ℃. 3. What is the chain boiler? Chain boiler, which is a particular kind of a boiler, a higher degree of mechanization layers fired boilers, the time the track grate with a chain similar to these so called chain boiler A boiler. Further, it is a pre-boiler, the coal combustion process is completed in the movement. Advantage of this kind of boiler, the combustion condition is stable, high thermal efficiency and easy operation, in addition, its low concentration of dust emissions. However, it should be noted that the moisture content of the larger, more ash and strong coking coal, not suitable for this kind of boiler for combustion. 4. How the moisture content in the flue gas boiler measured? Determination of moisture content in the boiler flue gas, which is the weight measurement method, condensation method, and three psychrometer, and the moisture content of the flue gas is typically in the volume percent of water vapor in the flue gas content to represent. If dark gravimetry, need to use hygroscopic agent, the hygroscopic agent used is calcium chloride, calcium oxide, silica gel, alumina, phosphorus pentoxide, magnesium perchlorate and the like.

Off state of the oil-fired boiler and approach the customer Q: oil-fired boiler flameout what state? How to determine whether the fuel gas boiler flameout it? Henan A fast boiler Company: Table fuel gas boiler furnace pressure instruction value suddenly increases; the furnace black, can not see the flame hole to see the fire; sound disappears combustion furnace; issued extinguishing the flame monitor signal; temperature, pressure abruptly fall, after the water level decreased and then increased, and so are flameout phenomenon. Auxiliary flame caused by an accident, such as a fan, blower power interruption, there is an accident signal emitted; fuel supply is interrupted as a result, oil-fired boiler fuel pressure is reduced to zero. If only a single burner flame, the furnace may also occur flame center deflected off the burner pressure changes; fuel supply is interrupted as a result, the extinguished burner pressure or hydraulic indication may drop to zero, while the other run burner fuel, gas pressure. After this occurs, must be timely treatment to ensure safe boiler. Customer Q: oil-fired boiler flameout, how can I deal with? Boiler Company Zhoukou City lofty Answer: Once a flameout must immediately cut off the fuel supply to the furnace, close the solenoid valve supply (supply and return oil), and then close the fuel supply valve in each operation of the burner. Operation action to be fast, so as not to continue or resume the supply of fuel, causing a risk of malignancy. At the same time, to identify the cause of the boiler flame, troubleshooting discovered, and then start doing the preparatory work. Before starting, we should strengthen boiler ventilation, purge, purge time is more than 5min, then procedures ignition. When the ignition is prohibited sent directly to the high temperature furnace fuel ignition without using an ignition device, in order to prevent dangerous accidents furnace. If due to fan failure caused when the flame, should quickly close the fuel supply line valves each, paying particular attention to the valve not tightly closed due cause fuel leakage. Meanwhile, according to emergency shutdown processing method for ventilating and purging of the furnace and the flue. After the fan resume operation, then step ignition. If only the burner flame, simply close the fuel supply valve to the burner, off throttle small oil-fired boiler, to identify and troubleshoot, and then re-ignition process the ignition. Be sure to quickly deal with properly in order to ensure the safe operation of the boiler.