Bath Center Natural Gas Steam Water Boiler Supplier

Luhai Gang, president of the other fast adhere to the strategic line of innovation and upgrading, were described in detail in terms of product innovation, research and development laboratory building construction, upgrade production lines, one-stop information management, so that you fully understand the fast boiler dealers in the market competition It has a brand, confidence in the next cooperation. Director of sales for the upcoming new products "Thalia T6" to explain. This is a set of premix combustion technology, wings tube condensing technology as one of the Subversive vacuum boiler, can meet various needs of users, or vacuum boiler industry will bring a new trend.

4 tons of fuel boiler Product description: 4 tons of fuel oil boiler is heated by a burner, fuel atomization effect, fuel combustion, can not see the chimney smoke, so the green fuel boilers, energy efficient. After spraying fuel through the burner into the furnace in the atomized droplets, and easily mixed with air and the rapid combustion heat flash. Compared with coal-fired boiler with the same capacity, and parameters, which furnace volume heat intensity may be increased about twice. But to reduce the thermal load of the burner zone, in order to avoid overtemperature waterwall tubes in this area, so the furnace volume is only reduced by about 1/3. Because the ash content of fuel oil is small, without slagging in the convection heating surface, it allows the furnace exit gas temperatures as high as 1300 ~ 1350 ℃, and narrow a pitch between the convection heating surface to increase the flue gas velocity, thereby increasing the heat transfer coefficient of the heating surface, the heating area savings and steel. Features: 1, the boiler burner automatic combustion control in accordance with instructions, stop, separate control box has a number of security, performance, security and stability, low maintenance. 2, the inner fire tube inserted spoiler retardant, smoke slow speed, to strengthen the heat exchanger, combustion heat conducting large extent to the water, the low temperature flue gas discharged from the smoke chamber, reducing heat loss and save fuel. 3, the water level sensor water level real-time monitoring, to continuously monitor the water level is normal furnace. While controlling the temperature and replenishment level sensor solenoid valves, the boiler water may be continuously supplied. 4, centrifugal multi-layer insulation glass wool, steel for packaging famous white color, heat loss, anti-rust appearance. 5, the product is widely used in hospitals, schools, hotels, hotel, bath center and other enterprises. Boot check: 1, various instruments, whether the instrument to confirm the adequacy of fuel tank, and the inlet valve is opened. 2, confirm the soft capacity and the water tank boiler water quality meets the requirements of the main valve is opened and boiler feed water inlet valve. 3, rotation of the oil filter to remove debris. 4, drain the remaining water in the boiler, while the opening operation of the low level alarm and chain. Boiling furnace process: 1, before the new boiler furnace should be boiled to remove impurities and dirt inside the boiler, or trisodium phosphate soda cooking oven may be employed to prepare a 20% concentration was added furnace (not note the solid directly into the furnace). 2, after closing the steam valve and the water table Hancock, opening the vent valve according to the procedure stoker firing power may be low heat and temperature rise at the beginning, when there is moisture in the furnace, close the vent valve when the valve is discharged from the vent, the furnace pressure is raised to be at around 0.1MPa, the boiler should be checked for leakage and various accessories such as fittings, if any leakage should be promptly fastened. 3, when the pressure in the furnace reached 0.3MPa, the normal shutdown program shutdown, let the furnace pressure decreased to 0.1MPa or less, the drain valve open, give up all the water in the furnace. 4, opening into the hole, rinsed with soft water inside the boiler until the washing water coincides with the degree of acid-base soft water, after closing and opening into the hole Hancock water gauge. 5, after the completion of cooking stove washing, all restore normal operation, before normal operation stoker.

Steam boiler pressure gauge should pay attention to matters 1. The rated steam pressure less than 2.45MPa steam boilers, pressure gauge accuracy of not less than 2.5; equal to the rated boiler steam pressure 2.45MPa, the pressure shall not be less than 1.5. Electric heating boiler and the boiler is mainly composed of electric control box and control system. Its characteristics are environmentally friendly, clean, no pollution, no noise, automatic, with limited energy and reduce prices significantly, as a new boiler electric heating boiler equipment increasingly being recognized. Electric heating the core member is electrically heated boiler, directly determines the life of the boiler, to select a non-metallic electrical heating tube (such as a ceramic heating pipe), because it is resistant to the load, a long life, and a water separation structure, the boiler Wing no leakage. There are heating and hot bath center steam water boiler supplier bath for two purposes. Hot water boiler by circulating hot water circulation pump hot water holding tank, the tank hot water heating cycle can be achieved bath object; hot water boiler by circulating hot water circulation pump heating conduit, through the heat sink (radiator) people can achieve heating requirements; hot water boiler and hot water circulating pump with heat exchanger can be achieved bathing and heating dual function. Dial gauge diameter of not less than 100 mm, to ensure that the operator can clearly see the surface pressure indication. 2. On the dial gauge steam boiler should draw a red line to indicate the maximum allowable working pressure. 3. The steam boiler pressure gauge should be installed in place to facilitate the observation and purged, and should prevent high temperature, vibration and icing. 4. The steam boiler pressure gauge should be checked at least once every six months, to be sealed lead-sealed after calibration. 5. The steam boiler gauge connection tube not leak water and steam, otherwise it will reduce the pressure instruction value. 6. A steam boiler pressure gauge measuring range should be compatible with the operating pressure of the device under test, the working pressure is generally 1.53 times, preferably 2 times the working pressure. Steam boiler no pressure gauge, pressure gauge or pressure gauge damage does not meet the requirements. When the steam boiler pressure gauge of the following circumstances, should stop using: 1. The surface of the glass or the dial pins; Lead seal, lead seal is broken or exceeds the calibration period; when no pressure gauge pointer position is limited to the limit staple nail can not be restored, and the rank unlimited gauge pointer movement from zero data is out of range pressure layer. Poor; leak or pointer jitter in the meter; other defects affect the accuracy of the pressure gauge. The use of the accumulator: the accumulator for a hydraulic system of the machine intermittently. It may be a low speed motion or intermittent motion of the actuator, the oil reservoir of the hydraulic pump, when rapid movement of the actuator requires a large flow rate, as an auxiliary energy supply to the system together with the hydraulic pump, enabling the pump and the entire hydraulic system miniaturization, to achieve energy saving. Hydraulic shock absorber valve and the opening and closing of rapid mutation load, the system generates a pressure shock, loved one causes vibration and noise and even damage the machine. The accumulator can relax and absorb the impact pressure of the liquid. Accumulators absorb and reduce the pressure pulsation flow pulsation and various hydraulic pumps, thus reducing noise and vibration system. The function of the gas spring having a damper, the vibration can be used to walk between the car body and the wheel and other mechanical absorption. The accumulator may be balance gravity vertical actuator (hydraulic cylinder) and the potential energy absorbing load drop into hydraulic energy storage, while producing speed resistance. When the rising vertical actuator, the accumulator absorbs energy of the original release, and together with the oil pump to the hydraulic cylinders, so as to achieve balance and energy.

20 ton oil gas steam boiler in a pharmaceutical factory

As we mentioned earlier, steam boilers are of great significance in pharmaceutical companies. We have supplied a 20-ton oil gas steam boiler to a pharmaceutical company overseas. In this pharmaceutical company, steam boilers provide heat for the disinfection of raw materials, sterilization of utensils, and drying of tannins. Our technicians provide customers with a 20 ton wns series oil gas steam boiler based on the information given by the customer.