bath center natural gas hot water boiler for sale

Several problems into a coal-fired boiler fuel gas boiler fired boilers changed several issues should be noted that the fuel gas boiler: fuel oil (l) high temperature corrosion of the fuel used in the boiler, containing an organic salt of a metal element as sodium, vanadium class, after combustion of the low melting point eutectic oxide crystals, generally of about 600 ℃, or even lower. These oxides sublimation at a high temperature furnace, then condensed in a lower relative temperature of the heated surface to form a high temperature corrosive fouling. Is characterized by high temperature corrosion: the metal began to appear at temperatures in excess of 580-620 deg.] C, the higher the temperature, the faster the etching. High temperature corrosion measures to prevent: l) the use of additives. Mainly magnesium, calcium oxide, hydroxide or dolomite (CaC03, MgCO3) and the like, these additives can generate a high melting point compound with the component acting in a high temperature fouling, the fouling becomes loose and shape, so as to avoid or mitigate high temperature corrosion. 2) use high temperature materials with good corrosion resistance, high temperature corrosion resistant chromium steel is better than the nickel-chromium steel. 3) coated with a protective film. Susceptible to corrosion in high temperature heating surface ceramic surface coating, a silicon carbide or silicon nitride special coatings, the heated surface may be aluminized other treatment to improve its high temperature resistance. 3) coated with a protective film. Susceptible to corrosion in high temperature heating surface and other surface-coated ceramics, silicon carbide, silicon nitride, or special coatings, the heated surface may be aluminized other treatment to improve its high temperature performance rot cloud. (2) low temperature corrosion in fuel sulfur generated during the combustion S02, since the fouling atomic oxygen present in the furnace and the convection heating surface and catalytic oxide film, SO2 is further oxidized to S03. S03 and H2S04 vapor in flue gas generated in conjunction with, the dew point of the flue gas containing the sulfuric acid vapor is greatly increased, when heated wall temperature below the dew point of sulfuric acid vapor will condense on the walls, and corrosion of the metal wall. Usually low temperature corrosion It occurs at the end of the air preheater of the boiler. Thus when burning high sulfur fuel, care must be taken to prevent low temperature corrosion. Prevent low temperature corrosion measures are: 1) low oxygen combustion. When the excess air at the outlet of the furnace lag coefficient down to 1.10 or less, for sulfur of the fuel oil used, the dew point of the flue gas will be significantly decreased, so as to avoid or mitigate low temperature corrosion. 2) use of additives. Sprayed into the furnace or flue additive in the curb generation of SO3 and to reduce the flue gas dew point temperature. Common additives solid (dolomite, limestone, magnesium oxide, and some special compound), the liquid (aqueous magnesium chloride solution, some oil soluble magnesium, calcium, zinc naphthenate compound) and a gas (ammonia gas, ammonia, three different ring) three categories. 3) raising the thermal wall temperature, so that it is higher than the dew point temperature of flue gas. Commonly used methods are: hot air recirculation inlet temperature of the air preheater increase; the installation of the heater core, air is heated by steam, a low temperature air preheater horizontal structure, the level of a horizontal pipe line is arranged an air preheater , the air flow in the pipe, the pipe between the smoke flow, erosion due to the lateral wall of the flue gas, the flue gas side heat transfer coefficient is increased to increase the wall temperature, more generally vertical wall temperature of the air preheater increase 20 ~ 25 ℃. 4) corrosion-resistant materials or corrosion resistant coating materials include glass, ceramics and the like; an anti-corrosion coating and had tried to enamel-coated surfaces like special steel anticorrosion paint. 5) timely sootblowing operation, and therefore should be a reasonable arrangement sootblowers. Fire and explosion of fuel failure (3) heating surface of the tail or incomplete combustion of atomized droplets gather in the tail of the heating surface, when it reaches ignition or explosion conditions, i.e., ignition and explosion may occur. The tail heating surface fouling aggravated by the possibility of aggregation of the oil droplets. Therefore, when coal-fired boilers into oil-fired boiler, burner should be correct and rational selection and delivery, and strictly develop from the induced draft fan. Rules and procedures for shutdown and normal operation to ensure good fuel atomization, with the wind reasonable. At each of the heating surface is arranged to be reasonable sootblowers. (4) determining the dew point temperature of flue gas is determined dew-point temperature of the flue gas has practical significance for the design and operation of flue gas dew point temperature factors influence mainly sulfur fuel ink, excess air coefficient, water vapor in the flue the amount of sulfur / cement ratio and combustion.

Since 2017, Yongji County, Jilin Province to respond positively to the State Council issued the "Air Pollution Prevention Action Plan" to carry out corresponding work strictly in accordance with national, provincial and municipal environmental requirements.

It is reported that out of Yongji County vigorously promote the renovation work of small coal-fired boilers, promulgated and implemented the "little out of Yongji County boiler work program" to develop "a furnace policy" policy, no longer approve new steam 10 t / h coal-fired boiler , while promoting the phase-out of small coal-fired boilers.

For small coal-fired boiler phase-out program has been effectively implemented, Yongji County Government has formulated "Yongji County eliminate small coal-fired boiler renovation award up approach", the county built area of ​​active users to carry out remediation work out of coal-fired boilers by small standard for financial awards complement, after the introduction of premium policy, and in the mouth before the town government to convene Yongji economic Development Zone, the area held a small coal-fired boilers user related meetings, arrangements for specific phase-out management work, and to a great extent to promote the progress of small coal-fired boilers eliminated.

Since the initial carry out small coal-fired boiler renovation work in 2017 to the present day, Yongji county built-up areas out of a total of 59 small coal-fired boiler units, a total of 16 sets of 20 tons of steam / hour non-electric and coal-fired boilers intention has been completed to upgrade pollution control facilities renovation work.

How to handle exceptions gas boiler? If the gas-fired boiler circulating pump only exception occurs, such as the current decreases, the pump outlet pressure returns to zero, indicating that the pump is idle, no oil, this may be due to the evaporation caused by the oil. Therefore, first, to find out the reason Young vaporized and take measures, such as filter clogging empty the circulating pump, the bypass should be opened immediately clean the filter; if the system does not exclude gas liquid water due to the new thermal caused or decomposition of water, air valve should open immediately. Circulation pump pressure constant, the current increases, flow decreases, metamorphism thermally conductive liquid, the viscosity increased, should be replaced or regenerated. Hot water boiler boiler assembly PC-style controller, all functions are stored on a smart chip, intelligent boiler, digitization, automation, humane, intelligent control of boiler water temperature, water temperature reached the heating automatically stop; large screen fonts display temperature, boiler water temperature at a glance. If the new heating electrically conductive liquid comprising water or system does not exclude the decomposition gas, the air valve should be opened immediately in the exhaust gas. When the current is below the normal circulating pump, a circulation pump showed reduced efficiency, decreased flow rate, which may be due to the fouling and clogging of pipes caused by the heating, to deal with stainless steel chain cleaning. If the differential pressure across the filter in the gas boiler is increased, the pump inlet pressure drops, the filter may become clogged, the bypass should be opened in order to dismantle and clean the filter.

Horizontal bath center hot water boiler for sale a few precautions, overpressure accident 1 boiler, steam boiler overpressure phenomenon of (1) a sharp rise in steam pressure, the pressure exceeds the allowable working pressure gauge pointer over the "red line" is still working pressure safety valve l high. (2) the operation of the device is the interlock overpressure protection, should send overpressure alarm signal, stops the air blowing, the wind, coal. (3) steam temperature and steam flow rate reduction increases. 2, to treat boiler overpressure (1) weakened rapidly burning, manually open the valve or bleed valve. (2) increase the water supply, while the lower reinforcing blowdown drum (It should be noted at this time to maintain the normal water level of the boiler), in order to reduce the temperature of the boiler water, thereby reducing the pressure in the boiler drum. (3) as a safety valve malfunction or all of the pressure gauge damage, emergency shutdown, safety valves and pressure gauges are to be repaired after the boost operation. When endanger the safe operation of (4) Boiler excessive pressure, blood pressure should take measures, but too fast buck is strictly prohibited. (5) boiler overpressure eliminate serious, to the shutdown of the boiler internal and external inspection, to eliminate the overpressure caused by deformation, leakage and other safety accessories and maintenance unqualified. Second, an accident boiler water, boiler water shortage (1) below the minimum safe water level line, or can not see the water level, the water level gauge glass (plate) as a white. (2) as a full-color water level gauge vapor instruction color. Low water level alarm signal (3) water level alarm occurs. (4) low water interlocking means, the water level should be below a prescribed value blower, Fan, grate reduction motor stops running. (5) a sharp rise in the superheater steam temperature, higher than the outlet steam temperature. (6) boiler exhaust gas temperature rises. (7) the water flow is less than the steam flow, causing Should the water tube due to tube cracking or economizer, an opposite phenomenon occurs. (8) When a serious water shortage, can smell the burnt smell. (9) When a serious shortage, the door can be seen from the red-hot waterwall tubes. (10) a serious water shortage, the furnace tube may rupture, then can hear the explosions, smoke and steam from the door, watching spray the fire door. 2, boiler water treatment (1) through the "waters", sentenced to severe water shortages, emergency shutdown must be prohibited blind to the boiler feed water. (2) through the "waters" sentenced to a slight lack of water, it should reduce fuel blast, the wind, and slowly feed water. Third, full water boiler 1 accident phenomenon (1) above the maximum allowable water level line, or can not see the water level, the water level gauge glass (plate) dark color boiler filled with water. (2) all of the water phase as a color level gauge indication color. High-water alarm signal (3) water level alarm occurs. (4) decreased superheated steam temperature. (5) water flow is not normally greater than the steam flow. (6) water in a large number of sub-cylinder, severe trap operation. (7) with a large amount of water steam severe, increased salinity, water hammer occurs in the sound of the steam pipe, the steam connection flange outwardly dripping take place. 2, steam boiler full of water treatment rinse water table, determined to be minor or serious full of water full of water. Method: Close water table, the water pipe connected cock, then open drain cocks As can be seen from the decreased water level, indicating a slight full of water, the water supply is stopped, the drain valve open, put to the normal water level. Such as severe filled with water due to take emergency shutdown measures.