hospital gas hot water fire tube boiler

After the gas hot water hospital hot water fire tube boiler hot water boiler vaporization emergency 1. Vaporization handler circulating pump stops abnormally pump failure caused by: ① blower stops running immediately. ② immediately open the door, take measures to pressure the fire, lift the chute gate, cutting off the supply of coal grate. ③ In the case of boiler pressure not greater than 0.6MPa (600KPa), the exhaust valve to follow, only a sharp rise in pressure in the boiler deflated, used only relief exceeds 0.9MPa, and the exhaust process to be carried out slowly, prevention boiler due to loss of pressure and more violently again vaporized. ④ close the boiler water, water main gas valve. ⑤ open stop valve recirculation line, to ensure that the water supply pipe velocity convection heating surface (economizer) to prevent re-vaporization of the economizer. ⑥ The operation of the above operation, at the same time to pay the boiler to reduce the boiler water temperature and the furnace pressure. ⑦ After the boiler pressure is normal, i.e., opening the standby circulating pump, into the normal combustion. 2. Treatment failure or sudden loss of power boiler vaporization of power: ① immediately open the door, lift the coal chute slide gate to take pressure fire measures to reduce the oven temperature. ② Grate with the fastest speed in order in the shortest time to fire onto the slag tap. ③ the degree of treatment in the first case. Once a short time can not supply heating network system, antifreeze should take emergency measures. 3. Due to excessive heat boiler boiler vaporization process: ① the immediate closure of the drum, induced draft fan. ② immediately open the door, take measures to pressure the fire, lift the supply of coal chute slide gate, off of coal, while the grate into fast gear. ③ In the case confirmed the presence of water, the boiler can supply water to the boiler body, boiler out of the water while closing the main valve. ④ Open line stop valve recirculation pump to ensure water velocity convection heating surface of the pipe, to prevent the economizer again vaporized. ⑤ Open circulating pump with jog mode, jog each time less than 30 seconds, again less than one minute jog interval. Jog purpose is to reduce the boiler water temperature, while preventing a large amount of steam into the pipeline system. ⑥ back into place after the safety valve, circulating pump running, and then the normal burning stove. 4. Water boiler system run vaporization process due to water loss, loss of pressure caused by: ① immediately closed drum, induced draft fan. ② out of the water while closing the main valve and the boiler circulating pump. ③ take the same measures to cool the furnace tube described above. ④ Open stop valve recirculation line. ⑤ rely exhaust valve until the safety valve back into place. ⑥ until the boiler water temperature drops below 50 ℃, when the temperature of the furnace temperature less number 200 ℃, again within the boiler feed water, water course to be carried out slowly, to prevent harm to the boiler when the temperature is too large. ⑦ After processing leakage fault, the system time to the replenishment, and out of the water boiler always open the valve, and the circulating pump, and then normal combustion.

We learned from Zhenjiang Municipal Environmental Protection Bureau, to further promote the Battle of Blue Sky, enhance air quality, the city actively carry out biomass hospital hot water fire tube boiler investigation and remediation work has been completed seven bathrooms demolition of straw biomass boiler work in built-up urban area .

Biomass boiler pollution remediation has been a major focus of air pollution control, some of the city bathhouses, hotels, restaurants in the use of raw materials process boilers, illegally blended with coal, waste wood, waste and other substances, not advanced treatment of smoke, nitrogen oxides and other pollutants directly into the atmosphere, some impact on air quality.

According to relevant regulations, Zhenjiang city, the city built the region prohibited the use of straw biomass boilers, the current investigation and the bathroom were 10 straw biomass boiler, in which 7 have been removed, two shutdown ready transformation. At the same time, straw biomass boiler outside the urban area will be completed before the end of June classification renovation work, all dedicated boiler using biomass briquette students, prohibit blended with other fuels, coal, wood, etc., and must complete the construction of the bag efficient dust embodiments, emissions guarantee compliance.

Condensing steam hospital hot water fire tube boiler in order to save more fuel to improve combustion efficiency: In order to improve the combustion efficiency, saving fuel, the fuel quality should be controlled, uniform atomization burner. Non-pressure condensing steam boiler indirectly heated hot water boiler, combustor or the like. To achieve the above object, the following points should be noted: 1 to understand the combustion principle, adjusting the wind ratio of positive oil (gas), to achieve efficient combustion; 2, to maintain a good working condition of the nozzle, the nozzle is not easy too large or too small, the nozzle wear obstruction, carbon status, to ensure good atomization combustion conditions. 3, to maintain proper pressure or hydraulic, pneumatic or steam boilers, such as high or low oil pressure, and a hydraulic or pneumatic pressure is too large or too small, will affect the mixing of fuel and air uniformly. 4, to adjust the burner flame length brains spray angle size and shape of the combustion chamber with fire furnace chamber filled eye, achieve economic combustion. No black smoke, no soot, in the good sense of the coming year running.

Maintenance of the contents of the fuel gas hospital hot water fire tube boiler month after a large number of dual-use survey data found that after regular maintenance gas-fired boiler, life, energy and the failure rate of maintenance should not be much more than regular maintenance of the boiler. Today, Zheng pot came to show you the contents of boiler maintenance monthly What? . A. The fuel supply line inspection: a light oil filter cleaning; ignition gas conduit 2 airtightness inspection; 3 checks whether the flow conduit.. B. inspection of the instrument: a flushing water table; 2 Syphons flushing; valve experiment. . C. Check burner: a flame detector (photocell) cleaning the light receiving surface; second inspection oil pump pressure is normal; 3 checks the combustion flame is normal; 4 check burner, the burner sound is abnormal; 5.... cleaning transfer cup; 6 o'clock washing water rod. . Check D. Intake system: a washing water filter; 2 reaches rated pump head and flow; 3 a check valve is working properly... E. daily drainage tank and the cleaning debris. Water quality testing, water testing furnace. F. Check the combustion consumption is normal.