gas oil lpg steam boiler in power station

SZS oil fired oil lpg steam boiler in power stationin ZG company is a typical watertube steam boiler. 15 ton SZS oil fired steam watertube boiler is with double drums and horizontal structure in designs. Its mainly parts includes double drums, membrane type water cooling wall, convection tube bundle and flue gas condensation recovery device. Oil fired steam boiler adopts “D” type layout which has advantages of small occupation area, easy to transport. This steam boiler adopts membrane water wall structure and the overall boiler uses airtight inner guard plate with full closed welding structure, the chamber wall has good sealing performance. This SZS IBR oil fired boiler adopts automatic burner, using continuous electric adjustment for water supply. It has high combustion efficiency, multiple protection function, safe and reliable operation.

Combustion gas treatment and a malfunction due to gas boiler burner ignition misfire bar: 1, the ignition bar gap interposed carbon residue with oil. 2, ignition rods fragmentation. moist. Leakage. 3, the distance between the ignition does not stick, too long or short. 4, ignition rods Insulation damage, short to ground. 5, ignition cable and transformer failure: cable, connector damage caused by a short circuit during ignition; transformer break or other fault occurs. Gas Burner fails, the action bar ignition misfire following five: Clear, renewal, adjust the distance, change and switching transformer. Second, the gas boiler the ignition spark rod misfiring but the reasons: 1, the disk space ventilation carbon cyclone is blocked, poor ventilation. 2, dirty oil nozzle clogging or wear. 3, the throttle angle is set too small. 4, the firing bar from the leading edge from the oil nozzle tip inappropriate (too protruding or retracted) 5, the first solenoid valve is an oil debris blocking gun (gun small kerosene). 6, oily or too viscous to flow easily clogged or the oil filtration system the valve is not opened, so that insufficient suction pump, oil pressure. 7, the filter pump itself blocked. 8, the oil more water (boiling abnormal noise within the heater). Gas boiler ignition spark rod action but misfiring are: clear; the first washing, such as not renewed; turndown test; adjusting the distance (in 3 ~ 4mm as well); Remove cleaning (cleaning the parts diesel) ; check the pipeline and oil filters, insulation equipment; peripheral screw pump removed, carefully remove the cover inside out net oil, diesel oil immersion; renewal of the test oil. Third, when the gas boiler and turn the fire a small fire normal, off, or flashing the causes of instability: 1, air volume damper setting fire too. 2, oil fires micro switch valve (damper outermost that group) inappropriate setting (set throttle air flow rate is greater than the fire). 3, oleaginous easy to spray viscosity is too high (heavy). 4, and the nozzle plate spacing cyclone inappropriate. 5, fire nozzle worn or dirty. 6, the preliminary fuel tank temperature is too high, so that the steam not smooth oil pump oil feed. 7, gas hot water boiler fuel oil water. When a small fire gas boiler normal and turn the fire extinguished or flashing instability action: Test gradually reduced; heating temperature; adjusting the distance (between 0 ~ 10mm); clean or replace; i.e., set to about 50 deg.] C may be; or drain oil change. Fourth, the noise increases gas boiler burner reasons: 1, cut-off valve is closed or the passage into the fuel shortage, an oil filter blockage. 2, the oil inlet temperature is low, the oil viscosity is too high or the temperature is too high the pump inlet. 3, oil pump failure. 4, fan motor bearing damage. 5, dirty fan impeller. Burner gas treatment increased noise: ① the check valve in the oil line is open, if the oil filter is working properly, the filter cleaning pump itself. ② heating oil or reduce the oil temperature. ③ Replace the oil pump. ④ replace motor or bearings. ⑤ cleaning fan wheel.

Fangkuai Company has a fully-automatic PLC intelligent control system designed and developed by itself with complete intellectual property rights. It adopts a combination of mechatronic control equipment and a programmable logic controller (PLC). Take the advanced programmable logic controller (PLC) as the "central processing unit" of the control system. The control system is operated through the touch screen, which greatly improves the degree of automatic control and operation reliability of the boiler, and the operation is simpler and more intuitive.

15 tph bagasse fired boiler means that the bagasse fired boiler can produce steam or hot water 15 tons per hour.And the price for 15 tph bagasse fired boiler is very cheap Compared with other boilers (such as ,coal fired CFB boiler,Oil gas fired power boiler,etc)