100kg per hour gas fired steam boiler

Fast one side condensing boiler steam condensate integrally advanced technology, with high efficiency, appearance, durable, cost savings, reduced noise, low nitrogen environmental advantages; self-developed by use of flue gas condenser waste heat boiler greatly increased thermal efficiency, while reducing emissions of harmful substances, can save a lot of fuel, compared with ordinary boilers, the average annual fuel cost savings of several million. Fast and well-equipped boiler unique cloud service 3.0 system, through remote monitoring of boiler operation, all-round ensure the safe operation of boiler.

Operation of the boiler, including what? Including the operation of the boiler, what does? Following on from the Henan fast boiler company to tell you about: 1. The water level regulation of normal water level in the middle of the gauge (1) of the boiler. Operation with the magnitude of the load is adjusted: to maintain a high level during low load, high load to maintain a low level. Changes should not be down more than 40 mm. (2) to be run on the water level gauge to compare the two groups, if the water level display should be corrected promptly identify the cause. (3) To achieve a balanced continuous boiler feed water, ground water supply, water supply less, to maintain the water level in the normal water level fluctuates slightly in the vicinity. (4) load change is large, prone to false level. Pay attention to judgment, in order to avoid misuse. 2. Steam pressure regulator (1) when the boiler must constantly monitor the pressure gauge indicated. To maintain stable steam pressure, boiler pressure must not exceed the design pressure. (2) increasing the boiler load: Steam pressure decreased boiler load is increased, if the level is high at this time, the amount of water should be reduced to a water supply or suspend, the amount of coal and increase the air volume. Gradually increase the amount of water at the same time to strengthen the burning, keep the steam pressure and the water level is normal. (3) boiler load reduction: the vapor pressure rises to reduce boiler load, if the level is high at this time, the amount of coal should be reduced and the air volume, reduced combustion. Then the appropriate water reduction or suspension of water supply to the water vapor pressure and stability in the nominal range. Then press the normal combustion and to adjust the amount of water. If the actual water level within the boiler is low, to increase the amount of water should, until the water level returns to normal after the combustion and needs to be adjusted according to the water vapor pressure and load changes. 3. Combustion adjustment (1) combustion index. Normal combustion boiler comprises a uniform supply of the fuel, reasonable ventilation, adjusting three basic aspects combustion. B. maintain a high temperature of the combustion chamber temperature of the upper layer is preferably in the 1100-1300 ℃, flame orange in color. Flame reddish color indicates that the amount is not enough to the wind, the color white indicates that excessive wind. It should be appropriately adjusted. C. fuel ash to reduce ash content in the combustibles to be below 10%. d. reducing the temperature of the exhaust gas boiler exhaust gas temperature should be controlled below 200 ℃. e. excess air negative pressure holding furnace boiler 1.2-1.4, by adjusting the balance of the blowers to maintain the furnace pressure is 2-3mm. F. to improve the thermal efficiency of the boiler thermal efficiency of the boiler should be kept above 60%. (2) adjusting the combustion a. Reasonable amount and the distribution of fuel to the amount of air needed for combustion. Ventilation should first increase the amount of fuel increases, it should first reduce the amount of fuel supply reduced ventilation. b wind principle feature: burn promoting intermediate ends. That is, after the coal into the coal starts to warm up the shutter, fire line front arch, the primary combustion zone, the middle grate to burn the rear grate zone. c is the normal combustion conditions: fuel ignition start at 300mm from the shutter of coal, even flames, the fire bed formation, at the end away from the combustion grate at the end of 300-500mm. d. Hold appropriate furnace temperature to avoid coking. E. fire bed to maintain the homogeneous combustion, to avoid burning fire bed obliquely. F. less than 30 minutes residence time of the fuel on the grate. Our company provides services related to the installation of the boiler!

Depending on the operating characteristics of electric 100kg per hour fired steam boilers, mainly to properly regulate the drum and induced draft fan. The chamber negative pressure is guaranteed ± (5-10) premise mm water column (water column ≈9.8Pa 1mm) to minimize the amount of the wind, to extend the residence time of the flue gas temperature in the furnace, reduce exhaust gas temperature.

Accessories szs system and boiler water tube boilers which (1) the fuel system the fuel system of pumps pumping fuel from the fuel tank to the day tank, is then withdrawn from the daily tank fuel pump, through a pressurized, heated, and sprayed into the filter oil atomization. This system is usually divided into the border daily service tank and oil supply system and fuel system. (2) feedwater, condensate water, steam condensate system piping system comprising pipes and valves and piping and other equipment from the deaerator. Steam system comprises a steam pipe and various valves. (3) the ventilation system features a ventilation system external air into the furnace for combustion of fuel, and the products of combustion (flue gases) discharged from the boiler to the atmosphere. In the process of air and flue gas flow, there will be a variety of flow resistance, if the natural ventilation generated by a chimney to overcome the resistance to flow, called natural ventilation. Obviously, this ventilation air flow generated is small, can be improved by increasing the height of the chimney natural ventilation. Using a fan to overcome the flow resistance of various ventilation systems, called mechanical ventilation. Mechanical ventilation is divided into positive pressure ventilation, ventilation and negative balanced ventilation. The so-called positive pressure ventilation means for sending air to the boiler and the flue gas discharged from the boiler to the atmosphere. Primer furnace boiler flue gas exhaust blower suction chamber, known as negative pressure ventilation. (4) boiler auxiliaries and monitoring instrumentation and monitoring instrumentation, boiler accessories boiler safe and economic operation are necessary, including: (A) as an annex to ensure the safe operation of the boiler: water level gauge, safety valve, pressure gauge and thermometer indicating steam parameters ; B) combustion supervision parts: pressure gauge, carbon dioxide indicator, oxygen table, smoking view mirror.