oil gas fired steam boiler price

Oil-fired boilers include oil-fired water boilers, oil-fired hot water boilers, oil-fired heating boilers, oil-fired bath boilers, oil-fired oil fired steam boiler prices and so on. Oil-fired boilers are boilers fueled by light oil (such as diesel oil, kerosene), heavy oil, residual oil or crude oil. Oil-fired boiler, gas-fired boiler, electric heating boiler is more economical than electric heating boiler and more convenient to use than gas-fired boiler compared with vertical oil-fired hot-water boiler.

The fuel can be natural gas boiler into gas-fired, city gas boiler, boiler coke oven gas, liquefied petroleum gas boilers and boiler; functions can be divided in accordance with KS-Q water natural gas boiler, CLHS / CWNS natural gas hot water boiler (including natural gas heating boilers and gas boilers bath), LHS / WNS natural gas and oil fired steam boiler price; can be configured in accordance with natural gas boiler is divided into vertical and horizontal natural gas boiler; flue gas flow can be divided according to a single backhaul gas three-pass boilers and natural gas boilers. Fuel oil-fired boiler is the difference between a fuel (such as diesel, oil, kerosene, etc.), natural gas boiler fuel is natural gas (such as natural gas, city gas, biogas as well as liquefied petroleum gas, etc.), depending on what fuel boiler combustion devices called burner, natural gas burner configuration called boiler natural gas boiler, oil boiler burner configuration called oil-fired boiler, oil-fired boiler and the difference between natural gas boiler that what fuel burners.

Combustion gas treatment and a malfunction due to gas boiler burner ignition misfire bar: 1, the ignition bar gap interposed carbon residue with oil. 2, ignition rods fragmentation. moist. Leakage. 3, the distance between the ignition does not stick, too long or short. 4, ignition rods Insulation damage, short to ground. 5, ignition cable and transformer failure: cable, connector damage caused by a short circuit during ignition; transformer break or other fault occurs. Gas Burner fails, the action bar ignition misfire following five: Clear, renewal, adjust the distance, change and switching transformer. Second, the gas boiler the ignition spark rod misfiring but the reasons: 1, the disk space ventilation carbon cyclone is blocked, poor ventilation. 2, dirty oil nozzle clogging or wear. 3, the throttle angle is set too small. 4, the firing bar from the leading edge from the oil nozzle tip inappropriate (too protruding or retracted) 5, the first solenoid valve is an oil debris blocking gun (gun small kerosene). 6, oily or too viscous to flow easily clogged or the oil filtration system the valve is not opened, so that insufficient suction pump, oil pressure. 7, the filter pump itself blocked. 8, the oil more water (boiling abnormal noise within the heater). Gas boiler ignition spark rod action but misfiring are: clear; the first washing, such as not renewed; turndown test; adjusting the distance (in 3 ~ 4mm as well); Remove cleaning (cleaning the parts diesel) ; check the pipeline and oil filters, insulation equipment; peripheral screw pump removed, carefully remove the cover inside out net oil, diesel oil immersion; renewal of the test oil. Third, when the gas boiler and turn the fire a small fire normal, off, or flashing the causes of instability: 1, air volume damper setting fire too. 2, oil fires micro switch valve (damper outermost that group) inappropriate setting (set throttle air flow rate is greater than the fire). 3, oleaginous easy to spray viscosity is too high (heavy). 4, and the nozzle plate spacing cyclone inappropriate. 5, fire nozzle worn or dirty. 6, the preliminary fuel tank temperature is too high, so that the steam not smooth oil pump oil feed. 7, gas hot water boiler fuel oil water. When a small fire gas boiler normal and turn the fire extinguished or flashing instability action: Test gradually reduced; heating temperature; adjusting the distance (between 0 ~ 10mm); clean or replace; i.e., set to about 50 deg.] C may be; or drain oil change. Fourth, the noise increases gas boiler burner reasons: 1, cut-off valve is closed or the passage into the fuel shortage, an oil filter blockage. 2, the oil inlet temperature is low, the oil viscosity is too high or the temperature is too high the pump inlet. 3, oil pump failure. 4, fan motor bearing damage. 5, dirty fan impeller. Burner gas treatment increased noise: ① the check valve in the oil line is open, if the oil filter is working properly, the filter cleaning pump itself. ② heating oil or reduce the oil temperature. ③ Replace the oil pump. ④ replace motor or bearings. ⑤ cleaning fan wheel.

Such as hotel Home Hotel Group is one of the three major brands, in 300 cities in the country has nearly 2,000 hotels. Home Inns has won China Golden Pillow Award for Best Chinese economy hotel chain brand award, in 2014, Home Inns brand value of $ 420 million of selected China's top 100 brands. April 4, 2016, BTG hotel groups such as the privatization of the hotel purchase transaction has been completed delivery. In mid-2016, as a Beijing hotel with our preliminary communication, the urgent need two boilers work of heating and hot water supply. I related technical engineers and recommend it to calculate the number and size of the boiler on the hotel room as hotel Willy sharp V6-99 two models.