For Sale 10t Natural Gas boiler Commercial Singapore

The arches of DHL Series Corner Tube Chain Grate Boiler can be redesigned according to the specification of the coal.

Reasonable requirements with the wind, it will cause the boiler coking. The ratio between each segment for the amount of wind, we need to determine good or bad based on coal quality, coal seam thickness on the grate, flue gas oxygen content, CO content, load size and other factors. For different loads and different combustion air in case of need to be summarized based on the ratio of long practical experience, the formation of a set of data in order to guide the operator to ensure the safety of energy-saving boiler operation.

In response to national environmental policy development, improve the quality of people's living environment of the area, Guangdong Province, actively promote the for sale 10t boiler commercial singapore "coal to gas" action. Currently, Dongguan City, "from coal to gas," the work has entered a crucial stage, nearly two months, the city government, city atmosphere Office, the Municipal Development and Reform Bureau has organized a thorough inspection teams to supervise the Towns "coal to gas" work . Atmospheric do inspection personnel Lurui Quan admits: "From the inspection situation, many companies on the 'coal to gas' is still in the wait and see attitude, worried about the safety and cost issues."

As of March 25, Dongguan City, 26 companies of 37 coal-fired boilers (except coal-fired captive power plant boilers), it has been out of the 17 units, 14 companies were using natural gas. In addition, 12 companies of 20 coal-fired boilers, is expected to complete phase transformation within this year.

It is expected that in the near future, all industrial boilers transform the use of clean energy, Dongguan sky will be bluer.

6 ton industrial wood fired steam for sale 10t boiler commercial singapore features:

1. Furnace and the two sides of burner zone adopts membrane water-cooled furnace structure. The membrane structure of wood fired steam boiler, our company’s solely design once used in electric boiler , is now applied in shaped assemble boiler. Its advantages lie in great thermal transmission heat, better heat transfer effect, lower heat loss ,better air impermeability, no wall distortion and no ash leakage.

2. The structure of arches adopts the newest technology --the upside”a” technology, which is awarded the national science and technology prize. The front arch is high and short while the back arch is low and long. And the part near the exit is inverse inclined type,while the front arch is 45ºinclined type, they together form a downside a flame structure,which makes the lean coal combustion easier and it can adjust itself to a wide rang of coal types. In this way, the flue gas is kept within the furnace a longer time, and the combustion efficiency is higher. The streamline shaped back arch can throw the non-burned carbon grains in the middle and back part of furnace to the front, so that the coal can be easier to be ignited and the ignition lines are tide.

3. The wood fired steam boiler adopts double layers or single layer layout structure, which can meet the customers’ requirements better.

You must know the for sale 10t boiler commercial singapore energy problems (induced draft fan power consumption rate, steam consumption) draft fan causes problems 1.1 boiler flue dust and fouling, in particular air preheater fouling, resulting in increased resistance to smoke duct . 1.2 boiler flue, tail heating surface and dust leakage. 1.3 Leakage Rate large air preheater. 1.4 furnace excess air coefficient is too large. 1.5 unit load changes, run the adjustment is not timely, resulting in furnace pressure is too large. 1.6 unit load or low frequent starts and stops. 1.7 coal into the furnace worse, from the design value. 1.8 low efficiency filter. 1.9 draft fan blade badly worn, low operating efficiency. 1.10 fan outlet flue gas desulfurization big resistance. 1.11 soda boiler pipes for leaks. 2, 2.1 to 2.1.1 operational measures to solve the problem of the strict implementation of soot blowing system to prevent the heated area ash, blocking ash, flue gas system to reduce resistance. 2.1.2 holding the induced draft fan, the flue gas separator baffles and dampers in the fully open position. 2.1.3 The experiment showed combustion boiler, proper control of excess air in the furnace. 2.1.4 adjustment chamber negative pressure, air leakage reduction furnace and the flue. 2.2 routine maintenance and testing 2.2.1 induced draft fan performance test to determine the optimum operating point and efficient workspace. 2.2.2 boiler, air preheater, a flue, ESP and other system leakage inspection, process. 2.2.3 timely check processing chassis, shaft seal leakage. 2.3C / D repair, eliminating defects 2.3.1 down strict accordance with movement clearance adjusting fan. 2.3.2 induced draft fan blade defect action elimination hand vane opening adjustment. 2.3.3 Importers and induced draft fan baffle opening check. 2.3.4 duct tightness check process. 2.3.5 wave plate replacement air preheater, rinsed sector plate gap adjustment. 2.3.6 eliminate dust defects and improve collection efficiency. 2.3.7 clean flue gas desulfurization system, flue resistance is reduced. 2.3.8 eliminate soda boiler pipe leakage defects. 2.4A / B repair and transformation 2.4.1 Check and repair the fan blades, replace seriously damaged blades if necessary. 2.4.2 for energy saving fan efficiency below 75%. 2.4.3 The fan motor frequency transformation. 2.4.4 of the precipitator, if necessary, transform and improve collection efficiency.