Seller coal steam boiler Commercial Thailand

Lujiang County, Anhui Province People's Government to strengthen the special equipment safety supervision, eliminate security risks, protect people's lives and property safety, recently, market supervision arrangements father of the rule of the mountain to carry out a special inspection of the boiler.

The area under the jurisdiction, boiler unit 10, involving 13 sets of boilers, mainly for industrial enterprises, food production enterprises. The audit focused on with the operation of the boiler, the boiler nature of the situation (coal, electricity, gas, biomass, etc.), verification test cases, water quality monitoring, troubleshooting, case workers certified, the implementation of the system, etc. . Examination revealed there is some use of units overdue inspection, the main responsibility is not implemented and so on, law enforcement officials immediately issued special equipment safety supervision instructions, the use of units ordered to stop using, to urge the rectification.

About six tons of seller coal steam boiler commercial thailand shutdown of a temporary shutdown: It is planned, therefore slow cooling during shutdown protection device, it should also pay attention to safety, pause furnace according to the rules in Chapter IV Fenghuo (pressure fire) get on. 2, safety shutdown: care should be completely stopped even on normal operation plan for 1 to 3 months to be a shutdown, shutdown should maintain more safety injection apparatus, after the shutdown, and other water-cooled furnace to below 70 ℃ when they let go of the gas, open manholes, hand holes, rinse the pot with water scale. 3, emergency shutdown: the boiler operation, when the case of the following circumstances, should an emergency shutdown, and notify the relevant authorities. (1) expanding the cease-fire should first see if the water table level is called to take water law. If Inception water table, water cock side, and then close the steam cock, and then turn on the water faucet open and close repeatedly called after water, still can not see the water. (2) All water supply equipment failure. (3) All water gauge, pressure gauge, safety one of all the failures. (4) a boiler or furnace wall element damage, serious threat to the safe operation of the boiler, emergency shutdown, should focus on preventing the stop of the accident and the specific steps as follows: ① first blowing off; ② the coal on the grate red raking; ③ Close induced draft fan.

Coal to natural gas operations bunch of factors that vertical pressure seller coal steam boiler commercial thailand energy consumption indicators of the country are carried out in a big way, the choice of vertical steam boiler, to a large extent minus the pollution of powder, together with nitrogen oxides and other dangerous gases the press has been discharged. Energy consumption indicators is an important rule to measure vertical steam boiler, to discuss the next bunch of factors under pressure vertical steam boiler energy consumption indicators. By analyzing the relevant departments, vertical steam boiler heat loss occurs mainly includes two aspects: the proportion of non-standard sufficient combustion air with exhaust heat loss. Weaken the heat loss can be retrofitted in the vertical steam boiler chimney terminal latent heat of re-use form, or in the selection of better boiler system FGR. Combustion air ratio is not sufficiently decomposed inappropriate criteria: ordinary vertical ejector-type steam boiler burner based, air-fuel ratio can not be formed in the active mobilization. More vertical steam boiler based on a mechanical blower burner, air-fuel ratio due to the following standards several factors: air-fuel ratio standard comprises two situations: when oxygen is excessive, the excess will be an infinite cryogenic air by heat conduction, caused by rising energy vertical steam boilers, low energy consumption vertical steam boiler index; when there is insufficient oxygen, there will not be sufficient to ignite the situation, leading to low energy consumption indicators vertical steam boiler.

Fire fighting methods inventory boiler in the boiler use, if a fire phenomenon, you know how to deal with it? Today, Xiao Bian teach you the recipe. When coal is poor or low load, it may be administered less number, to maintain a high pulverized coal concentration, but can not chipping operation or asymmetric operation. Load is less than 170MW, should remain A, B powder layer to stable operation, when any failure to a powder, should be administered stable combustion, the failure to the powder to be put into operation, combustion stability, and then exit the gun run . Adjustment of the amount of the low-load air supply, to maintain the oxygen 4-5%, and adjust the opening degree of the auxiliary windshield. If it is a bad case of fire, may be appropriate to increase the primary air temperature, wind speed reduces time, but not overshoot the spark plugs burned once or blocked ducts. When the job should be strictly periodic system and to reduce powder powder switching system, dust bunker normal position at least 2.5 meters, so that a stable working state bunker, at each adjusting shutter powder to powder, the powder as far as possible amount consistent and stable, no spark plugs to prevent dust and to dust gravity caused by combustion fluctuations. Should maintain acceptable fineness of pulverized coal, according to chemical analysis, after adjusting the test plate to open Classifier, coal is poor or low load, it may be appropriate to increase the fineness of pulverized coal, in order to facilitate combustion. Maintain normal milling system, powder separator shall not clogging the tertiary air pinkish large deterioration in combustion. Furnace can eliminate air leakage and air leakage milling system, all view of the fire without plugging holes, play Giocondo, etc. should be tightly closed. Value of the long should keep abreast of the situation of coal and coal quality fuel, combustion instability occurs when, such as when a fault powder, coal mutation, the differential signal changes drum is too large, the oil should immediately cast coal combustion stability and taking samples for analysis. High load, the premise of ensuring steam temperature, combustion can be appropriately adjusted to prevent the shift of the center of the flame, so that the furnace exit gas temperature rise, caused by coking. Operator adjusting the main steam temperature may be employed with positive pagoda wind run, the central flame stabilizer. Should be a bellows pressure control as a basis for wind speed, in time to observe the duct pressure and temperature, the premise of ensuring primary air duct is not blocked, a bellows pressure should not exceed 4000Pa.