slaughtering and processing gas hot water atmospheric pressure boiler dealer

The impact of fuel hot water slaughtering and processing hot water atmospheric pressure boiler dealer energy consumption indicators of the country has been engaged in a pile of incentives impressive work of coal to natural gas, fuel oil boiler with hot water, greatly minus the dust pollution, while discharging harmful gases such as nitric oxide has also been inhibition. Energy consumption indicators is a key measure of marked oil hot water boilers, to discuss incentives under the influence of a pile of hot water boiler fuel consumption indicator of subsequent. Through research departments, oil hot water boiler heat losses arising primarily from the comparison of two parts: non-standard air-fuel ratio combustion with smoke exhaust heat waste. Reduce smoke emissions from waste heat can be converted in hot water boiler fuel waste heat recycling install smoke trailing, or leading with more types of condensate recovery boiler. Combustion air-fuel ratio is inappropriate Standard Decomposition: Usually based fuel ejector type hot water boiler burner, air-fuel ratio can be formed mobilization maneuver. Many hot water boiler fuel based on a mechanical blower burner, resulting in a standard air-fuel ratio causes are several later: air-fuel ratio is mainly divided into different from standard probability comparison: when the airflow in excess, there will not be excess cold air It is heated, causing the oil hot water boiler energy consumption rise, low energy consumption indicators of fuel hot water boiler; when there is insufficient air flow, insufficient to ignite the situation will occur, causing low energy consumption hot water boiler fuel indicators.

The quality of the horizontal gas fired slaughtering and processing hot water atmospheric pressure boiler dealer directly influence the property of the boiler. Meanwhile the alerting and protection directly influence the safety and liability of the oil protection. The control system of the gas fired boiler main includes burner control, the control of the water level,pump constant pressure for oil control.

How to handle exceptions gas slaughtering and processing hot water atmospheric pressure boiler dealer? If the gas-fired boiler circulating pump only exception occurs, such as the current decreases, the pump outlet pressure returns to zero, indicating that the pump is idle, no oil, this may be due to the evaporation caused by the oil. Therefore, first, to find out the reason Young vaporized and take measures, such as filter clogging empty the circulating pump, the bypass should be opened immediately clean the filter; if the system does not exclude gas liquid water due to the new thermal caused or decomposition of water, air valve should open immediately. Circulation pump pressure constant, the current increases, flow decreases, metamorphism thermally conductive liquid, the viscosity increased, should be replaced or regenerated. Hot water boiler boiler assembly PC-style controller, all functions are stored on a smart chip, intelligent boiler, digitization, automation, humane, intelligent control of boiler water temperature, water temperature reached the heating automatically stop; large screen fonts display temperature, boiler water temperature at a glance. If the new heating electrically conductive liquid comprising water or system does not exclude the decomposition gas, the air valve should be opened immediately in the exhaust gas. When the current is below the normal circulating pump, a circulation pump showed reduced efficiency, decreased flow rate, which may be due to the fouling and clogging of pipes caused by the heating, to deal with stainless steel chain cleaning. If the differential pressure across the filter in the gas boiler is increased, the pump inlet pressure drops, the filter may become clogged, the bypass should be opened in order to dismantle and clean the filter.

It is understood, Henan Luyi Bureau of Quality Supervision two clear priorities, strengthening from coal-fired slaughtering and processing hot water atmospheric pressure boiler dealers governance, strengthen clean coal regulatory two-pronged approach to help air pollution prevention and control.

In strengthening the management of coal-fired boilers, the council of 10 tons of steam coal-fired boilers and below will not carry out the inspection expires, no new ban in combustion zone, converted biomass briquette high-polluting fuel boilers. We found that the use of such boilers shall be banned according to law, be removed. 10-35 tons of steam per hour are no longer registered coal-fired boilers, in such boilers to urge them to a "coal to gas" or "coal to electricity." Currently, the county five of these boilers have been converted completed, emissions compliance, through acceptance.

Clean coal in strengthening supervision, the county council for production and sale of clean coal technology strict customs inspection. Staff depth of the county two clean coal production enterprises, the enterprise quality management system, laboratory use, production site, production and sales ledger, source of raw materials, the main responsibility for security, the key point of control the production process unfold strict supervision inspection, testing every batch of their products, to eliminate substandard coal products into the market.