Agent Price 2t Natural Gas steam boiler Myanmar

Principles of agent price 2t steam boiler myanmars and solutions hydraulic external gear of Henan fast boiler's small series with you about the principles of steam boilers and solutions Steam Boiler hydraulic external gear in accordance with the fuel (electricity, oil, gas) can be divided into electric steam boilers, oil three kinds of steam boilers, gas and steam boiler; constructed according to the steam boiler can be divided into vertical, horizontal steam boiler, steam boiler compact than a single, double return of the vertical structure, large steam boiler return of more than three horizontal structure . If the classification according to top standards, in the form of steam boilers on the lot, would like to give an ordinary packaged boiler say four tons vapor. Water in the steam drum is heated to become vapor, fire emits heat in the furnace, it is the principle of the steam boiler. Steam boiler combustion section and drive means by a chain grate, a combustion chamber together with the pan rack frame formed on a grate composition. Four weeks envelope refractories. From coal fired into the hopper, the shutter coal front portion while sealing air control seam thickness. Blowing into the combustion chamber is a lower place, such steam boilers greater resistance, require forced air. Steam boiler cinder burn out, the rear portion of the grate by the "beak iron" discharged from the slag out of the furnace feeding machine. Steam boiler flue gas from the back of the boiler, the steam drum of a boiler return line before the smoke tube, returned by two return rear smoke tube, and then into the dust separating ashes, and then discharged through the chimney draft fan. These are the works of steam boilers, steam boilers run course, ultimately, other devices, such as induced draft fan not only bear the task of exhaust fumes, or negative pressure necessary for operation of the steam boiler. As well as pressure vessels, thermometer, safety valves, pressure gauges, pumps, steam pumps, and so on. They are essential for steam boiler work. Pump leaks. Gear pumps for leaks during operation, leading to its actual output is smaller than the theoretical flow of traffic. The main channel is leaking gear pump: through the gap between both surfaces and both side surfaces of the gear cover side leakage, accounting for 75% to 85% of the total leakage of the pump; radial gear tip circle between the inner hole and the pump CLEARANCE ; gap by engagement of the gear leak. The gear pump due to the presence of a leak, so that the output pressure do not increase, the influence of the use of a gear pump. In order to solve the low gear pump output pressure problems, may be employed on both sides of the elastic gear plus floating collar or baffle manner, to reduce the leakage of the gear pump, the gear pump to increase the output pressure. Radial force imbalance. In the gear pump during operation, the pressure acting on the outer gears are not equal, resulting in the gear and bearing at the axle radial imbalance force. This unbalanced force will accelerate the radial bearing wear and reduce the service life of the bearings, the gear shaft deformation can also cause friction with the inner hole of the addendum pump, pump damage, so that the pump does not work. The solution generally adopted is: ④ opening pressure balancing grooves to the pump, the high pressure oil introduced into the low pressure zone, but will increase the pump leak, the influence of the volumetric efficiency of the pump; ② size reduction oil pressure chamber, acting on the teeth the pressure area is reduced, thereby reducing the radial force imbalance.

Since 2017, located in Changchun City, Jilin Province to accelerate the governance of coal-fired boilers within the city out of small coal-fired boilers remediation process. Up to now, the work has achieved initial success.

15 in the city with 20 kilowatts and above the coal-fired generating units, 13 units have ultra-low emissions; city table 292 with 20 t steam / hour or more coal-fired boilers, emission standards have reached the count 253 male , accounting for 86.64% of the proportion of the boiler with; the city built area of ​​10 steam tons / hour small coal-fired boilers 2962 units, out of a total of 29553 units, up 99.7% out of proportion, the basic completion of the national requirements out of the task.

In order to further improve air quality, improve people's living environment standards index, Changchun City by expanding the ban on burning area, improve the standard phase-out of coal-fired boilers, plans to use two years of urban 20 tons of steam / h coal-fired boiler (kiln) furnace eliminated.

By the end of 2017, the city has eliminated 20 tons of steam / hour coal-fired boilers 964 units; at the same time to speed up the central heating and (expanding) network as well as the pace of clean energy promotion, provide for the transformation of the city's coal-fired boiler control a strong guarantee.

In recent years, Changchun City, adhere to the full implementation of coal-fired boilers governance, to improve ambient air quality in Changchun City has played a positive role. 2017, good days Changchun 276 days, compared with 2013, an increase of 35 days; heavy pollution days 10 days compared to 2013, reduced by 33 days; major air pollutants respirable particulate matter (PM10) and fine particles (of PM2.5) were 78 mg / m and 46 micrograms / cubic meter, respectively, 39.5% and 37.0% decrease over 2013.

Operation of the boiler, including what? Including the operation of the boiler, what does? Following on from the Henan fast boiler company to tell you about: 1. The water level regulation of normal water level in the middle of the gauge (1) of the boiler. Operation with the magnitude of the load is adjusted: to maintain a high level during low load, high load to maintain a low level. Changes should not be down more than 40 mm. (2) to be run on the water level gauge to compare the two groups, if the water level display should be corrected promptly identify the cause. (3) To achieve a balanced continuous boiler feed water, ground water supply, water supply less, to maintain the water level in the normal water level fluctuates slightly in the vicinity. (4) load change is large, prone to false level. Pay attention to judgment, in order to avoid misuse. 2. Steam pressure regulator (1) when the boiler must constantly monitor the pressure gauge indicated. To maintain stable steam pressure, boiler pressure must not exceed the design pressure. (2) increasing the boiler load: Steam pressure decreased boiler load is increased, if the level is high at this time, the amount of water should be reduced to a water supply or suspend, the amount of coal and increase the air volume. Gradually increase the amount of water at the same time to strengthen the burning, keep the steam pressure and the water level is normal. (3) boiler load reduction: the vapor pressure rises to reduce boiler load, if the level is high at this time, the amount of coal should be reduced and the air volume, reduced combustion. Then the appropriate water reduction or suspension of water supply to the water vapor pressure and stability in the nominal range. Then press the normal combustion and to adjust the amount of water. If the actual water level within the boiler is low, to increase the amount of water should, until the water level returns to normal after the combustion and needs to be adjusted according to the water vapor pressure and load changes. 3. Combustion adjustment (1) combustion index. Normal combustion boiler comprises a uniform supply of the fuel, reasonable ventilation, adjusting three basic aspects combustion. B. maintain a high temperature of the combustion chamber temperature of the upper layer is preferably in the 1100-1300 ℃, flame orange in color. Flame reddish color indicates that the amount is not enough to the wind, the color white indicates that excessive wind. It should be appropriately adjusted. C. fuel ash to reduce ash content in the combustibles to be below 10%. d. reducing the temperature of the exhaust gas boiler exhaust gas temperature should be controlled below 200 ℃. e. excess air negative pressure holding furnace boiler 1.2-1.4, by adjusting the balance of the blowers to maintain the furnace pressure is 2-3mm. F. to improve the thermal efficiency of the boiler thermal efficiency of the boiler should be kept above 60%. (2) adjusting the combustion a. Reasonable amount and the distribution of fuel to the amount of air needed for combustion. Ventilation should first increase the amount of fuel increases, it should first reduce the amount of fuel supply reduced ventilation. b wind principle feature: burn promoting intermediate ends. That is, after the coal into the coal starts to warm up the shutter, fire line front arch, the primary combustion zone, the middle grate to burn the rear grate zone. c is the normal combustion conditions: fuel ignition start at 300mm from the shutter of coal, even flames, the fire bed formation, at the end away from the combustion grate at the end of 300-500mm. d. Hold appropriate furnace temperature to avoid coking. E. fire bed to maintain the homogeneous combustion, to avoid burning fire bed obliquely. F. less than 30 minutes residence time of the fuel on the grate. Our company provides services related to the installation of the boiler!

As this consumer added, he wants to fire gas fuel and automatic operating system. Thus, our sales manager recommend him WNS type, single drum, horizontal structure, firing oil and gas. WNS 2000 kg agent price 2t steam boiler myanmar working together with autoclave can ensure the brick manufacturing process smoothly and successfully. Its horizontal structure and integrated design is very good-looking, and convenient to transport.