2t Natural Gas steam boiler Commercial Cheap Cyprus

Boiler steam temperature affect the safety and economy temperatures above will be lower than the rated temperature of the device, it will have a bad effect. If the temperature exceeds its rated value, the boiler will cause overheating of the relevant metal material, material creep acceleration, will shorten the life of the boiler. If the temperature is too high, but some of the key components of the boiler would cause damage, can also cause serious and even superheater tube rupture. If the temperature is lower than the rated temperature, vapor enthalpy is reduced, increased air consumption, decreased economy. This will reduce the thermodynamic cycle efficiency of the plant, the steam humidity at the last stage blades of the gas turbine increases, causing erosion and damage to water droplets gas turbine blades, affect the safe operation of the gas turbine. Ruoyin with water vapor causes a decrease in temperature, the moisture in the salt impurities formed in the superheater scale, pipe valves, gas turbine blade, because the superheater lead to reduced heat transfer, the temperature decreased, damage increased wall temperature; and cause the valve plug, the operation failure; and a gas turbine blade erosion, loss of balance and vibration occurs. Temperature fluctuations reason superheater actual heat transfer the vapor does not reach the required amount of heat absorbed corresponding balancing. When the heat absorbed is greater than the heat transfer, the temperature rise; conversely decreased. Many factors affect the temperature change, including both gas side and the vapor side. Such as boiler load increased, but also to ensure the boiler load unchanged or decreased in order to prevent pressure shall increase the amount of fuel and air supply, strengthen the burning, causing the furnace exit flue gas temperature of the flue gas volume increases and lower water temperature , temperature increase; If the oil and gas fuel is combusted in the furnace carbon black is not fully formed, into the superheater flue causing secondary combustion, but also greatly increase the superheat temperature. Reducing the temperature of the main reasons: improper adjustment of combustion, low flame center furnace; superheater area is small, or too much leakage at the furnace wall; Save water flow rising or temperature reduction; drum water level or high gas-water separator separating efficiency is lowered, the humidity of the vapor is increased; superheater tube fouling, reduced heat absorption and the like.

Winery method which reduce pollution 1, check for leakage protection and maintenance of: 2 mm steam leakage will cause energy losses of more than 10 tons of coal each year do? When you do not use it, you can turn it off to save energy. For water, steam and compressed air leak survey and routine maintenance, cost very little. 2, the non-contact cooling water in repeated use: Since the non-contact cooling water temperature and the quality is very good, it can be reused for desizing, scouring, rinsing and other processes. Three best source of cooling water is regenerated: sintering machine, a pre-link and compressor systems. The plant water recovery system may be installed, pipes, valves, storage tanks, and control systems. 3, repeated use of steam condensate: S. Mills requires a lot of saturated steam in the dyeing process, wherein a portion of the condensate is converted to its high temperature and purity. Water can be pumped back to the boiler to form a new steam. For those who buy steam from suppliers, or boiler is located away from the dyeing process, the condensate can be used as water washing or desizing. 4, pre-treated wastewater reuse Procedure collected bleaching, mercerizing machine, the water can be reused in other programs, there is no direct discharge of wastewater. 5, hot wash water is recovered from the hot gas in the dyeing process, large amounts of hot water are used to wash. Heat the washing water can be collected by the system plate heat exchanger to preheat the water to be sent to the next washing. 6, pre-screened coal enterprises should introduce screening spiral coal boiler technology to selection of raw materials. It is possible to improve the media tell the good, the bad quality of proportion, to avoid loss of small volumes of coal and coal calorific value. 7, maintaining steam traps traps can help maintain effective delivery of the steam plant. The valve is removed from the steam pipe and prevent further condensation water, so as to avoid heat loss and reduce fuel consumption. 8, the piping, valves and heat insulated flange experience pipes, valves and flanges waste of resources, reducing efficiency. Steam delivery device insulated to prevent vapor loss is an inexpensive, energy-saving method of .9, the heat recovery from the boiler chimney at a temperature of 360 ℃ smoking, sometimes discharged directly into the atmosphere, there is no heat recovery. In fact, this heat can be used to preheat boiler water, steam or create a new steam system. 10, optimization of compressed air systems consume a large amount of compressed air in many parts of the winemaking equipment Mills. These instruments are prone to leakage, particularly in a threaded joint, rubber joints, valves, automatic regulator, the inflatable device and the old gasket. In addition, the use of compressed air pressure is usually based on the maximum pressure setting; reduce this pressure is feasible and would not have any negative impact manufacturing.

Dairy production and processing sectors, need a lot of steam on food drying, sterilization, stereotypes, such as processing, 2t steam boiler commercial cheap cyprus essential. Xinjiang Ake Su Xinnong Dairy Co., Ltd. as a local brand, has a large market users. 2016, Akzo increased demand for dairy production, the original steam boiler company can not meet today's production needs. In the same year, Akzo dairy cooperation with our company, signed a series SZS 6 tons of steam pipe steam boilers, steam support for the dairy industry dairy production Aksu.

Steam and hot water boiler water level gauge fault safe hydraulic machine operating company of Henan fast boiler with small series to introduce a common 2t steam boiler commercial cheap cyprus water gauge Problem safe operation of steam and hot water boiler water gauge failure of hydraulic machine, the causes and solutions approach a hot water boiler steam water gauge reason and common problems: 1, the water level is too low mounting table; 2, water table, even the water pipe is too small; table 3 have low level or a water level indicator, when active, only one only water table; 4, the ground water table, drain cocks no drainage; 5, a drum water level on the table is valid, another water table damage; 6, the tap water gauge screw fixed; 7, the tap water gauge leak, leaking; 8, the performance of the water table level false; 9, the drum water level in the water table irregularities two inconsistent; water gauge glass often broken; 11, water level gauge glass without guard; 12, water gauge low water level glass plate not shown in the red line instructions; 13, glass plate dirty water table, the water level observation is unclear. The main reason is because of 1-4 above design, installation or alteration of dislocation caused. When the steam boiler with a low water table position when the drum is only a case of the water table, water table because the internal balancer lowland leakage short-circuit (at that time can not be detected), resulting in the emergence of lowland water table high water level ( the so-called full of water), and the water table on the drum performance but low water level (or even probably not see the water level), then the fireman because they can not determine the true level of the boiler will go immediately and check the water level in the drum on the table, it will be very serious water shortage in container delays when the boiler accident occurred. Glass-sided water table in front of a glass sheet metal frame box lined with asbestos pad contact surface made of cardboard and then screw the cover frame and the cover pressure closely. Some even show the water level too low trust status of the water table, and take a little sewage, mistakenly steam boiler water when filled with water incident handling, accelerate the production of the accident, there is precedent for such incidents to be investigated. Then, the above-mentioned reasons hinder 5-9 problem occurs mainly boilers lasting not run when washed in water table, not routine maintenance, resulting in water gauge cocks rust, gas, water and even the block, or insufficient packing or aging deterioration. False water level phenomenon, in addition to gas, water or even the cock pipe is blocked, but also could be vapor, the water pipe connected to the water table caused by misalignment connection; steam, water tap handle installed the wrong position resulting cock closed, since there poor water quality, the boiler priming and thrown false water level. Water gauge glass is broken mainly steam, water faucet centerline not aligned, the presence of glass bending stress; long glass without expansion gap; water table is at the window glass is a cold draft, and the glass pipe quality was poor. Safe operation of hydraulic machine 1, hydraulic machine operator must be trained to master the equipment performance and operating techniques to work independently. 2, before the operation, you should clean up various debris on the mold, wipe any dirt hydraulic rod. 3, the mold must be installed hydraulic machine in case of power failure, and prohibit the collision start button, the lever foot on the footswitch. 4, installed on the upper and lower dies, the die gap adjust, unilateral allowed off-center, a good confirmation of the fixed mold pressure again. 5, before the hydraulic machine is first started working apparatus idling 5 minutes while checking whether enough oil tank, pump noise is normal, the hydraulic unit and pipes, fittings, if the piston leakage phenomenon.