10 billion kcal gas steam boiler in iran

What are the precautions in the loading and installation of gas-fired 10 billion kcal steam boiler in irans?

Gas-fired steam boilers are a very wide range of special equipments, widely used in food, chemical, paper, textile, construction and other industries. In the process of loading and installing a gas steam boiler, some problems must be paid attention, otherwise it may cause a certain degree of economic loss.

1. Pay attention to the following matters during the loading and unloading and handling of gas-fired boilers: the lifting capacity of the lifting equipment should match the weight of the lifting boiler. The lifting lug on the boiler with the lifting lugs that cannot be used for lifting can not be used for lifting. The length of the steel cord should be reasonably selected to avoid the scratching of the furnace due to the improper length of the steel cord. The boiler must be protected from any damage during handling and handling.

2. Reserves for maintenance space When installing boilers, ensure that there is sufficient maintenance space around the boiler.

3. Setting and precautions for the base and base of the gas steam boiler The boiler body must be installed on the basis of 100-150mm above the floor of the boiler room. It must be confirmed with the technical personnel of the boiler manufacturing company in advance and constructed according to the basic drawings. The anchor bolts must be reserved on the foundation. The foundation shall be capable of withstanding the maximum weight of the boiler and the amount of water it holds. When installing the base, you must first position it. After positioning, adjust to the same length of the two diagonals of the base, and then tighten all the fixing bolts. The installation of the base is carried out with reference to the reference line.

4, general precautions Be careful not to tilt and impact the boiler and accessories too much. No combustibles can be placed around the boiler. Do not use oil and water to smother the boiler. The boiler should normally be installed in a separate boiler room. The new gas-fired boiler room should not be connected to the house. The boiler room shall not be connected to Class A, Class B and Category C fire hazard rooms using flammable liquids. If connected to other production plants, the application firewall is separated.

5. The fire resistance grade and fire protection requirements of the boiler house building shall comply with the requirements of the Code for Fire Protection of Building Design and the Code for Fire Protection Design of High-rise Civil Buildings. The ground of the gas steam boiler room should be flat, non-flammable, no water accumulation, and the foundation load should meet the requirements. The power supply voltage of the gas steam boiler room should be stable to avoid causing the electrical components to burn out. If the voltage is unstable, it is recommended to install a voltage regulator. Ventilation equipment should be installed in the boiler room, and the boiler should be kept at room temperature below 50 °.

Vertical 10 billion kcal steam boiler in iran combustion characteristics combustion grate section with double action, heating up, fast boosting of unburnt gas through the secondary combustion, functions as combustion, smoke, dust. Bending the upper furnace tube arrangement convection heating region, disposed in the lower furnace grate tubes and radiation heating furnace area, structure of the furnace and the flue gas flow, reasonable layout, good heat transfer, the boiler reasonable design, simple structure operation, easy maintenance, small footprint, less investment in infrastructure, the company is one of small enterprises with steam, heating and other equipment ideal. Coal-fired steam boiler performance characteristics: 1, the furnace and comparing the old vertical boiler, heating area, rapid boost heating, less coal, high thermal efficiency, can save 25-30% of coal. 2, a furnace with multiple, user-friendly, the furnace can be used for the production of steam steaming canteens, disinfection tableware, bath heating, process steam, heating and the like locally heating the room. 3, the furnace with natural ventilation, induced draft fan and the blower does not need, no noise. 4, compact structure, installation, operation, easy maintenance, may be integrally handling, suitable flowability units. 5, heated with steam bath, food, heating, steaming, etc., pressure gauge scale strictly controlled within the design pressure, working pressure at any time shall not exceed the operating pressure. The scope of the steam boiler Application: can be used in textile, printing and dyeing, paper, food, rubber, plastics, chemicals, pharmaceuticals, iron and steel, metallurgy and other industrial products machining process required steam, and for enterprises, institutions, hotels, schools, restaurants, service industries such as heating, bath, air conditioning and hot water. Pledge: Since the equipment installation qualification pressure parts warranty 3 years, 12 months, auxiliary and lifetime maintenance, warranty period free of charge warranty for non-human failure (various defects caused by faulty equipment itself) of the Company, the replacement of damaged parts, the warranty period or man-made damage, is still responsible for maintenance and guidance equipment, for repair, replacement parts only fees. Quality assurance after the expiry responsible for maintenance of life.

Heard so much about fast boiler made a number of achievements in the areas of clean boiler, this time my unit and quick cooperation parties, give me your company's boiler unit is in line with the requirements of our team boiler, to achieve a clean, energy-saving, environmentally friendly way of heating . Moreover, your company for the Beijing authorities have provided more office cleaning boilers, a good reputation. So, we finally reached a cooperation. --customer feedback

Gas boiler which has few parts of the main gas boiler: the enclosed pipe chimney pipe tube sheet base gas outlet steam dryer Confining the majority of the peripheral tubes to form a complete gas boiler. The main effect of gas boiler: the combustion of the fuel is heated by the feedwater temperature and the exothermic heat of the flue gas with a heated surface, so that a final water into superheated steam having a quality of qualified certain parameters. The water in the boiler to go through preheating, evaporation, overheating in three stages in order to become superheated steam. In fact, in order to improve the efficiency of the steam power cycle, there is a fourth stage, i.e. re-superheating stage, soon after the high pressure turbine expansion work to reduce the pressure and temperature of the steam back to the boiler is heated and then sent to the low pressure turbine cylinder continues to work. In order to meet these four phases change, the boiler must be arranged in the respective heating surface, i.e. the economizer, water wall, superheater and reheater. Superheater and reheater disposed in an upper horizontal flue backpass and functions of the fuel system is to ensure the desired fuel burner. The fuel oil burner system are: tubing and fittings, pumps, solenoid valves, nozzles, heavy oil preheater. The gas burner mainly a filter, pressure regulator, solenoid valve, and then firing solenoid valve, the fuel valve. Economizer disposed in the lower back pass. In order to utilize flue gas heat of heated air required for combustion, usually air preheater arranged after the economizer. Some additional preheating large boiler superheater heating surface or in the furnace, and then heat-receiving surface.