boiler Commercial Dealer 20t Vietnam

How to save electricity when using electric boiler commercial dealer 20t vietnamFirst of all, we first find out the power consumption of electric boilers, the main reason is poor insulation performance and improper use. As a result of improper use, the electricity bill will of course be increased a lot. So how should we save electricity? 1, your building indoor height. 2, indoor heating temperature. 3, the direction and number of floors of the room. 4, outdoor temperature. 5, adjacent to the living room heating. 6, Indoor doors and windows insulation effect. 7, the wall insulation conditions. 8, user methods and so on. Then the power configuration of the electric boiler should be reasonable. The power configuration is too big or small, but the power configuration is too large instead No power configuration, more tips. Power configuration is too small, the electric boiler has been working to achieve the set temperature, but also can not reach the set temperature. This is because the electric boiler fills the room with less heat than the room heat loss, the room heating is slow and not obvious, not only waste electricity, but also can not play a comfortable heating effect. People run at low temperatures when they are away. The electric boiler system has thermal inertia, can not be heated up immediately when it is opened, and can not be cooled immediately when it is closed. When you are away from home, turn down the temperature instead of shutting down the system, or shut down the boiler when you are away for a long time. Reasonable utilization of peak and valley electricity. Use of nocturnal valley electricity, with a slight temperature Fine-tuning, can even use a heat storage tank, peak electricity during the day, the temperature down. The house should be well insulated. Good thermal insulation can prevent excessive heat loss, doors and windows can not have obvious gaps, windows had better add double-layer central control glass, wall insulation, energy-saving effect will be very remarkable.

3, boiler commercial dealer 20t vietnam overpressure

Boiler overpressure operation, ranging from components can cause deformation, damage joints; can also cause severe explosion.

Inspection 6 tons of steam boiler commercial dealer 20t vietnam pressure parts of introduction 1, the steam boiler Safety Supervision boiler if the following conditions to deal with various internal and external inspection and pressure parts overpressure test. (L) disassembly, after conversion and shifting means; (2) stops running and resume operation requires more than one year; (3) pressure-receiving element after major repairs; (4) according to the boiler operation, the state of the device must doubt when tested. 2, the boiler before the test is completed stopped, the elimination of the internal scale external boiler ash, soot, yet necessary to dismantle the furnace wall and the insulation cover, the following check Key: (l) when the drum welds, holes and the like are normal , for leakage; (2) presence or absence of corrosion of the boiler plate, where the groove from deformation and the like; (3) waterwall tubes are not bent, deformation, etching, etc. inflated; (4) a pyrotechnic tubes are not bent, the tube plate out and gusset weld cracks; (5) to the water pipes, sewage pipes and the welding drum presence of a defect. 3, severe corrosion do accounting should be done before the super strength test. 4, before the hydrostatic test should do the following tasks (l) portion of the test, the internal management and Pu inspection surface; (2) to check the clogging of pipes; gauge (3) is mounted in the modified inspection (no less to 2); (4) change means drains and purge valve. 5, in a hydrostatic test shall meet the following requirements: (l) hydrostatic test shall be carried out when the ambient temperature is higher than 5 ℃, measures should be adopted or against the cold. (2) filled with water boiler, if the metal surface condensation, should be removed, a preliminary check for leaks and then slowly open the booster, when raised to 3kg / CM, a check should be carried out, can be tightened if necessary manholes , hand holes and flange bolts; (3) when the water pressure up to operating pressure, the opening pressure should be temporarily stopped to check for any leakage of each portion, and then increased to the test pressure for 5 minutes and then back down to the operating pressure checks, meet the following requirements is eligible. ① In the test pressure was raised, the pump stops, the pressure drop must not; no leakage in the outer weld ②; ③ watermark (traces of water) may or tears (not downflow drops) not being replenished weld; ④ Water after the pressure test, visual observation found no residual deformation.

Due to the special nature of the industrial park location, we are more to consider whether the boiler commercial dealer 20t vietnam with green features in the choice of boiler equipment. According to our survey of the entire boiler industry, quick side has considerable experience in research and development in the field of environmental cleaning boilers, boiler equipment while also providing low pollutant emissions for Beijing more enterprises and institutions, we are fully confident that the fast boiler ability. --customer feedback