Wns Oil Gas Fired Steam Hot Water Boiler

8 ton condensing fuel gas-fired boilers in Russia

ZG boiler re-export project—a full set of 8 tons of condensing fuel gas-fired boilers was exported to St. Petersburg, Russia. As the economic power of Russia, St. Petersburg takes industry as the main development point, and is a highly developed international city of science, technology and industry. Therefore, the selection requirements for production equipment are very high. The ZG boiler oil and gas boilers feature the internationally popular classic “all-wet-back three-return” design structure, FRG flue gas recirculation, condensation prevention and control, and other special technical advantages to enable Russian customers to successfully sign a complete set of 8 tons of WNS with ZG boiler within a week. Type saturated steam boiler contract, the fuel is natural gas and diesel. In addition, based on Europe's strict boiler emission standards, ZG boiler has configured pure Italian imported burners for customers.

Car accessories types of complex processing, such as the interior wall Peng, floor, seats, instrument panels, sound systems, many processes required in a high temperature environment, the temperature becomes optional metrics wind Visteon wns oil fired steam hot water boiler. It is reported that Dongfeng Visteon existing boiler equipment can not reach the growing production needs, the introduction of fast boiler production of two parties often piezoelectric hot water boiler (CWDR1.8-95 / 70-II) in 2017.

Henan oil-fired boiler Introduction Product Introduction: Henan oil-fired boiler to run than electric heating boiler economic, easy to use than gas-fired boiler. With economic development and social progress and the improvement of people's awareness of environmental protection, coal-fired boilers due to serious pollution, moving away from sight, replaced by a new environmentally friendly digital boiler, such as electric heating boiler, oil boiler, gas boiler, electric heating boiler is more expensive, gas-fired boilers need to open a gas pipeline, then, if there is no gas pipeline, and hope boiler low operating costs, only select oil-fired boiler. Boot check: 1, various instruments, whether the instrument to confirm the adequacy of fuel tank, and the inlet valve is opened. 2, confirm the soft capacity and the water tank boiler water quality meets the requirements of the main valve is opened and boiler feed water inlet valve. 3, rotation of the oil filter to remove debris. 4, drain the remaining water in the boiler, while the opening operation of the low level alarm and chain. Features: 1, inserted within a fire retardant spoiler tube, slow speed exhaust enhance heat transfer, the temperature of the flue gas discharged from a low smoke chamber, reducing heat loss and save fuel. 2, furnace by computer-aided design, each of the heating surface is optimized, compact and reasonable arrangement, small boiler area, high thermal efficiency. 3, the user can set the start, shutdown time, after setting, no special duty, easy, and effort. 4, according to the boiler pressure furnace design, furnace provided with a top opening to atmosphere, the boiler is in an unpressurised state, there is no risk of explosion. 5, the inner fire tube inserted spoiler retardant, smoke slow speed, to strengthen the heat exchanger, combustion heat is conducted to a large extent in water, the discharged flue gas temperature is low smoke chamber, reducing heat loss and save fuel. 6, the water level sensor water level real-time monitoring, to continuously monitor the water level is normal furnace. While controlling the temperature and replenishment level sensor solenoid valves, the boiler water may be continuously supplied. 7, water boiler fuel water speed, water volume, widely used in factories, hospitals, schools, etc. required a large amount of boiling water units. Shutdown procedure: 1, when it is desired to deactivate the combustion boiler to the switch in the OFF position, the oil supply is stopped, the flame is extinguished, but the fan is still operating to blow away the residual flue gas in the furnace. 2, when the blower is stopped, the operation OFF switch to turn off the power and then, after closing the steam valve, and the fuel supply valve to close the valve. 3, open the drain valve when the discharge pressure is reduced after the boiler play an open valve, to drain the water in the boiler, and the steam partial open the drain valve to drain the water in the drum segregation. Daily checks: 1, check the water level regulator function: whether the automatic water pump stops. 2. Check flame monitoring. 3, is rotated, the slide cam portion lubricating, and wiping. 4, the flushing water level gauge 1-2 times (class), according to the proper operation, so that until the rinse water level gauge. 5, sewerage 1-2 times (class).

Hot water boiler heating mode, which has several? Indirect Heating boiler water: high temperature hot water supply system, and by directly converting the high temperature hot water heat transfer station is a low temperature and a low temperature heating system running hot water. The system contains two separate high and low warm water circulation, two lines standing pressure. Due to the heating system in their assembly separate water circulation system, high and low temperature circulating pump system, a separate area, the presence of equipment investment, operation maintenance, staffing, secondary energy consumption, infrastructure investment, covers and many other issues. Daily fuel tank wns oil fired steam hot water boiler provided steam heating means and electrical heating means, hot water boiler when cold start ignition furnace, because there is no electric heating steam, hot water boiler when the ignition is successful and handover immediately after the steam generated steam heating. Indirect heating of running hot water boiler with high viscosity heavy oil, in addition to a mechanical pulverizer means daily heater heating the oil in the tank to supply the service required corresponding to a temperature suitable viscosity, the heavy oil is pumped to Front heater - secondary heater again, the latter is to meet the needs of high temperature water boiler oil atomization nozzle. Thus, the heavy oil mainly for secondary heating boilers burning fuel, the other part is small in the circulation tank return line back into the household.