Industrial 6t Natural Gas steam boiler Cheap Philippines

About the kind of industrial 6t steam boiler cheap philippines fuel oil boiler steam through the next, there are many main purpose, main features, a brief Automatic fuel gas steam boiler. A: The main purposes: food processing, printing and dyeing, pharmaceutical production and provide steam to provide steam sterilization, medical institutions, enterprises and institutions to provide steam for the other, the hotel's heating Automatic fuel gas steam boiler, the heating can also provide domestic hot water tank by . Second: The main features: 1, with central back burning structure, a large volume of water and gas boiler space, adaptable load capacity. 2, the indoor micro-pressure flame automatic steam boiler fuel combustion, the flame is fully extended, enhanced heat transfer, thereby reducing convective heating area, reducing the cost of the boiler. Smoke flow resistance is small, low-power consumption operation, operating cost savings. 3, in addition to the conventional four level height control, an additional level detector 5, the detection bit will stop when the boiler water, alarm, to ensure safe operation of the boiler. 4, the front smoke box special heat insulation materials, high temperature, low thermal conductivity, good anti-radical quenching heat capacity, greatly extending the life center back burning boiler before the smoke box, the furnace insulation is multilayer glass wool , light weight, low heat loss. 5, automatic oil-fired boiler steam pressure is controlled by Danfoss and Danfoss pressure controller and pressure transmitters joint control, pressure controller is responsible for ultra-high pressure interlock protection, prohibits burner working and alarm; pressure transmitter responsible for combustion engine to work to achieve some or all of control, to achieve automatic control of the exact steam pressure and steam pressure in the pressure range provided by a touch screen, detecting a pressure up to 0.002 MPa, more accurate pressure control. Thus avoiding a pressure controller general requirements of the production and the high vapor pressure of low pressure gas boiler or the actual requirements of the production of high pressure and low pressure gas boiler can not meet the disadvantages of the production requirements. 6, flue gas condenser fast side (optional) by the national utility patent, requires efficient use of steel-aluminum sheet Chi spiral tube heat exchanger, heat transfer surface is sufficient, the small side of the flue gas resistance of the system to meet the general burner. With flue gas condenser heat boiler efficiency can be improved more than 8%, the fuel gas savings of nearly 10%. These are the simple on automatic steam boiler fuel introduction want to be useful.

0.5 tons gas boiler introduced: 0.5 tons of gas boiler Description: 0.5 tons of gas boiler imported burner, automatic programmed control, automatic purge blower, electronic auto-ignition, spontaneous combustion and gas, (air) automatically adjusting the ratio of wind oil good atomization, combustion, low NOX, energy saving and environmental protection. Under normal circumstances, when the boiler steam pressure reaches the set value, the burner combustion is automatically stopped, when the steam pressure is below the set value, the burner is automatically started. When the abnormal phenomenon of the fuel, air intake, fault lights, the output sequencer will immediately stop the fuel, burner shut down automatically.

To introduce industrial 6t steam boiler cheap philippines pressure gauge and hydraulic press accumulator using steam boiler pressure gauge should pay attention to: 1, rated steam pressure is less than 2.45MPa steam boiler, the accuracy of pressure gauge must not be 2. 5; Rated steam pressure large or equal to 2.45MPa boiler, pressure must not be less than 1. 5 class. The diameter of the dial of the pressure gauge shall not be less than 100 mm to ensure that the operator can see clearly the surface pressure indicator value. 2. A red line should be drawn on the pressure dial of the steam boiler pressure gauge, indicating the maximum allowable working pressure. Steam boiler pressure gauges should be installed in a place that is easy to observe and wash. 4. Steam boiler pressure gauges should be checked at least once every six months, and should be sealed with lead after calibration. 5. Steam boiler pressure gauges should not have leakage of water and steam leakage in the connecting tubes of the pressure gauges of steam boilers. (4) the steam boiler pressure gauges should be checked at least once every six months and sealed with lead. 5. Otherwise, the pressure indicator value will be reduced. 6. The measurement range of the steam boiler pressure gauge should be adapted to the working pressure of the measured components, usually 1.5 times of the working pressure, preferably 2 times of the working pressure. Steam boiler does not have pressure gauge, the pressure gauge is damaged or the installation of pressure gauge does not meet the requirements, steam boiler pressure gauge should be stopped when one of the following conditions: 1, broken surface glass or dial calibration mold There is no clear paste; 2, no lead seal, lead seal damage or beyond the calibration period; 3, without pressure, the pressure gauge of the finite pin can not be restored to the limit pin, the infinite position of the gauge pointer deviated from zero data beyond the allowable pressure clothing; 4, gas leakage or pointer jump in the meter; 5, other defects that affect the accuracy of the gauge. Purpose of the accumulator: the accumulator is used in the hydraulic system of intermittent machinery, which stores the oil output of the hydraulic pump during intermittent or low-speed movement of the actuator, and when the rapid movement of the actuator requires a large flow rate, As an auxiliary energy source, together with the hydraulic pump, the oil pump is supplied to the system, thus the oil pump and the hydraulic pump are realized. The miniaturization of the whole hydraulic device absorbs the quick opening and closing of the impact hydraulic reversing valve and the sudden change of the load. The system will produce shock pressure, the darling will lead to vibration and noise, and even damage the machine. The accumulator can mitigate the impact pressure absorption pulsation of these fluids absorb and reduce the flow pulsation and pressure pulsation of various hydraulic pumps thus reducing the system noise and vibration. The damped accumulator acts as a gas spring and can be used to absorb the vibration between the fuselage and wheels of walking machinery such as vehicles. The balanced accumulator absorbs the gravitational potential energy of the vertical actuator (hydraulic cylinder) and its load as it falls. When the vertical actuator rises, the accumulator releases the original absorbed energy and supplies oil to the hydraulic cylinder together with the pump, thus realizing the balance and energy saving.

Directly under the Central Government Offices Administration (referred to as the straight Authority) is the CPC Central Committee and subordinate units, are responsible for the CPC Central Committee and services for the organs and services, an important function of serving the people. Central Government institutions funds, finance, public service vehicles, the state-owned assets and real estate management, service management is responsible for the specified life of the party and state leaders as well as services related objects.