Commercial Dealer 6t Natural Gas steam boiler Turkey

Fast boiler has been to uphold the "mold character, and create boutique" business philosophy, after learning of the status of the state forest mountain elementary school, we are non-stop, quickly prepare a large number of teaching supplies, to the mountains in order to improve children's education hardware conditions positive contribution. In order for children to drink purified water clean and sanitary, after the group discussion after deliberation, determined to provide six sets of water purification equipment and pipeline machine. Teachers and students by means of this device can drink safe water purification, we can say that they know how these "water" next to the Red Flag Canal precious. Watching the children line up smiling face after the contact of water, we all feel distressed bursts.

Measures to improve the thermal efficiency of the fuel gas-fired boiler wns type of chemical oil-fired boiler which is incomplete combustion heat loss and mechanical incomplete combustion heat loss. Because almost no ash after combustion of the gas boiler, solid and liquid fuels without mechanical incomplete combustion, there is no need to consider the mechanical incomplete combustion of the gas boiler heat loss. In all heat losses, heat losses have tremendous proportions, when the high thermal efficiency of boilers, heat losses so the total loss of the main heat losses of fuel gas-fired boiler flue gas heat loss is the exhaust gas temperature and For air excess factor. When the exhaust gas temperature decreases, high thermal efficiency can be obtained, for example, a conventional three-pass commercial dealer 6t steam boiler turkey, furnace used in the past straight and smooth smoke tube, must increase the heating surface is arranged to make the exhaust gas to an acceptable degree, the theoretical discharge around the smoke heat loss. Potshell causing significantly increased diameter, wall thickness increased, greatly increased metal consumption, thus further reducing the exhaust gas temperature should be greatly restricted. From the aspect of heat transfer is not only now consider only the heated area, the use of new technology enables heat transfer performance significantly increased, the difference between the heat transfer overcomes the disadvantages of the past performance of the boiler, so that the exhaust gas temperature decreases, the structure is more compact. Center back boiler combustion boiler is preferably small foreign structure, although the two-pass boiler, the heated area is small, but the use of the turbulator charming, the purpose of enhancing the turbulence of the flue gas, disrupt laminar flow boundary wall, reducing the thermal resistance, increasing the heat transfer coefficient, a smaller heating area to achieve the same high thermal efficiency. Lower exhaust gas temperature limit in theory, the exhaust gas temperature can be reduced to very low or even close to the ambient temperature, for maximum thermal efficiency. However, in practice, due to the reduction of the exhaust gas temperature, low temperature corrosion will cause, therefore, the exhaust gas temperature can drop too low, in order to ensure that the wall temperature is higher than the main boiler heating surface flue gas dew point temperature. Therefore, low-temperature corrosion has become a major obstacle to reduce exhaust gas temperature and improve the thermal efficiency of the boiler. Tail auxiliary heating surface increases, further reducing the exhaust gas temperature, fuel gas wns improve thermal efficiency of the boiler as the oil, gas fuel burn easily wns type gas boiler air preheater generally not disposed. The economizer means is a common energy, which can be recycled flue gas was able to effectively reduce exhaust gas temperature. Separation type condensing gas boiler is out of the main boiler heating surface, the installation of the condensing heat exchanger. In one aspect of the flue gas absorption can significantly reduce the smoke temperature, reducing heat losses, on the one hand the absorption of part of the potential condensing water vapor released, increasing the effective use of heat of the fuel. Ash cleaning, to ensure that the heating surface of the scale wns boiler thermal efficiency of the boiler, the presence of soot fouling and heat transfer resistance increases, reducing the heat transfer effect. The thermal conductivity of the scale and soot is almost of the same order of magnitude, with the increase in scale, soot, the exhaust gas temperature rapidly increases, the thermal efficiency is significantly decreased. So, keep the boiler heating surface inside and outside clean, efficient heat transfer, thermal efficiency and to ensure the safe and economic operation of boilers, boiler fuel gas-fired boiler ash cleaning is required.

After electric commercial dealer 6t steam boiler turkey shutdown, how maintenance? When long-term disabled electric steam boiler, furnace should pay great attention to external corrosion and maintenance problems. First, after power shutdown cooling steam boiler, the ash must be thoroughly cleaned and the heating surface fouling the upper grate, the lower portion of the furnace. Then to maintain a certain degree of natural ventilation flue. In general, in order desiccant moisture should be placed in the furnace, flue. The quicklime as a drying agent, within the furnace or flue gas per cubic meter should be placed generally about 3kg. After placing all the ventilation should be tightly closed doors. After the change of lime powder to be replaced. Low-lying position as boiler room, ground during shutdown severe flood tide, often approach should be used and placed a small fire to dry desiccant combination. If the boiler shutdown a long time, after the complete removal of soot coated with an anti-corrosion red lead paint in oil or other metal surface furnace. As for anti-corrosion maintenance methods inside the furnace shutdown, the shutdown Yaoan the length of time to be. In general, no more than one month shutdown maintenance wet available, more than one month should be taken to maintain dry. To note the following problems when a dry maintenance: desiccant boiler not in direct contact with the metal surface, may be mounted in a container such as the iron plate after the desiccant is placed, and a hole for shutting the other hand hole cover, valve steam, the water pipe change must cut lime powder should be replaced.

Steam boiler commercial dealer 6t steam boiler turkey price Price: works steam boiler is heated in the drum and water is converted into steam, fire gives off heat in the furnace. Qiang boiler plumbing materials sales center is located in the southern suburbs of Datong City, is a design, sales, installation and service of integrated modern enterprise management. The main environmental operating boiler, a steam boiler fired boiler, a heating furnace, steel radiators, cast iron radiators, canned motor pump, the pump piping, air-conditioning water, galvanized pipe, PP board tanks. Details can be found! Works (in Pulverized example) in the furnace pulverized coal combustion heat is first absorbed water wall heat transfer by radiation, boiling and evaporation of the water wall to enter a large amount of steam for steam separator drum (excluding the DC furnace), into the separated saturated steam superheater heated by flue gas at the top, and the horizontal flue gas flue continue to be absorbed radiation and convection, superheated steam reaches a predetermined operating temperature. Generating boilers usually equipped with a reheater is heated by high pressure steam cylinder. Reheater steam power generation is continued into the low pressure cylinder. 1, the working principle (as an example in pulverized coal fired boilers) in the furnace pulverized coal combustion heat is first absorbed water wall heat transfer by radiation, boiling and evaporation of the water wall to enter a large amount of steam for steam separator drum (except for the DC furnace ), the separated saturated steam enters the superheater heated by flue gas at the top, and the horizontal flue gas flue continue to be absorbed radiation and convection, superheated steam reaches a predetermined operating temperature. Generating boilers usually equipped with a reheater is heated by high pressure steam cylinder. Reheater steam power generation is continued into the low pressure cylinder. 2. Pulverized coal boiler operation, the position of the center of the flame will affect evaporation. Generally, low center of the flame will lead to greater evaporation, and the high center of the flame will lead to slow evaporation. Also affects the position of the center of the flame superheated steam or reheat steam temperature. Typically, superheated steam, in particular the reheat steam temperature in the lower center of the flame, and vice versa. 3. Pulverized Coal Burner front and rear walls is arranged a thrust manner, tangential firing mode, bis tangential firing methods, each method has its own characteristics. Since the above-described arrangement can not be applied in the same furnace at the same time, the influence of steam can not be directly determined.