gas fired hot water boiler in gorakhpur

Steam boilers What is the function? Too many in the form of steam boilers, would like to give a quick four tons of ordinary steam boiler talk. Water in the steam drum is heated to become vapor, fire emits heat in the furnace, it is the principle of the steam boiler. Let me say a boiler pot. This boiler is a boiler drum with a water cooling wall at about the subregional arrangements drum pyrotechnic two return pipe, before the folded portion of the drum front smoke box. Between the drum and the tank in connection with the downcomer tubes and water-cooled bi, constituting the frame of the combustion chamber. There upper steam separator drum to reduce the water vapor out of the tape. Pan heating surface of a lower portion of the drum, and the water cooling pipe bi pyrotechnic tube. A chain grate combustion section and drive means, coupled with the combustion chamber pan rack on the frame configuration composed of the grate. Four weeks envelope refractories. . From coal fired into the hopper, the shutter coal front portion while sealing air control seam thickness. Blast into the lower part of the combustion chamber is a place that boiler greater resistance, need to force the blast. Cinder burn out, through the grate in the rear portion of the olecranon iron discharged from the machine to send out of the furnace slag. The boiler flue gas from the rear, by the front drum smoke tube a return line, the return from the two rear return smoke tube, and then into the dust separating ashes, and then discharged through the chimney draft fan. Not only is the induced draft fan exhaust fumes, the negative pressure of the boiler operation is required. Steam boiler pressure vessels, safety devices is necessary. Boiler necessary water level gauge, pressure gauge, safety valve, thermometer, and under the pressure of the electric pump can pay, and the vapor pump when power is off can also be used. Boiler water must be softened, as well as water treatment equipment.

When we use the boiler, it is unavoidable to have faults or abnormal phenomena, but in order not to affect the normal use, when the boiler appears problems should be dealt with in a timely manner, then in the face of all kinds of circumstances, how should we deal with it? Share with you some ways to handle exceptions. If only the boiler circulating pump abnormal, such as its current reduced, outlet pump pressure return to zero, which means that the pump is idling non-oil, may be caused by vaporization of oil. Therefore, first of all, Yang should take measures to identify the cause of vaporization; if the filter blockage causes the circulating pump to empty, the by-pass cleaning filter should be opened immediately; such as the new heat transfer fluid containing water or Water-decomposing gas is not excluded in the system, then the open valve should be opened immediately. If the circulating pump pressure is constant, the current increases and the flow rate decreases, the heat transfer fluid is metamorphic and the viscosity is increased, so it should be replaced or regenerated in time. If the gas containing water or decomposing is not excluded from the system due to the new heat conduction fluid, the gas should be discharged immediately by opening the valve. When the current of the circulating pump is lower than the normal value, it shows that the efficiency of the circulating pump is lower and the flow rate is decreased, which may be the fouling blockage of the heating pipeline, and the stainless steel chain should be cleaned. If the pressure difference between the front and back of the filter in the boiler increases and the pressure of the pump inlet drops, the filter may be blocked. The bypass should be opened and the filter should be turned on. Remove cleaning. In addition, the low outlet temperature of the liquid-phase heat carrier furnace and the lack of heat supply are mainly due to the problem of ash accumulation, so soot-blowing should be carried out in time. A more common problem with the boiler's grate is that it is stuck because it is broken or loose after the pin has fallen off; metal inclusions in the coal trap the grate; the grate is arched; and the tip of the slag stopper sinks to jam the grate. In view of this phenomenon, it is necessary to clean up the debris with the plate hand-down converter row, replace the broken furnace platoon and start again, if it is stuck again after the start-up, then check the causes after stopping the rotation and solve the problem in detail. At the same time, it is necessary to adjust the screws on both sides and tighten the grate, if it is still not correct. Often, you need to change the sprocket.

Xiamen Rui Yi Hotel is available straight left Gulangyu the most beautiful views of the BRIC countries delegations designated top hotels, the best location in the heart of Xiamen, modern trends and classic style pavilions. The hotel features well-appointed room service, fashion and superior restaurant, bar, meeting rooms and a gym, swimming pool and other recreational facilities, people feel contented and comfortable. Projects and programs as Xiamen Rui Yi Hotel Xiamen City landmark hotel building, attaches great importance to environmental protection philosophy, which party fast boiler manufacturing philosophy coincide. In late 2016, the two sides signed an electric steam boilers for hotel supplies disinfection work, since the electric steam boiler, any security incidents never happened, Rui Yi Hotel ensure normal operation.

Gas boiler price related factors and their dust: the gas boiler in the boiler, which is one of the website products, and further comprising a gas fired hot water boiler in gorakhpur, gas steam boilers, gas oil furnace three. Therefore, it is necessary from a whole, to know and understand, so that we can help further their specific products, and at the same time, to increase the amount of their own knowledge in this area. 1. gas boilers and electric boilers, which one is better? Gas boilers and electric boilers, boiler compare the two, then, can not say which one is better, because there is no comparable. I can only say, under what circumstances, what kind of boiler more appropriate. Moreover, both the boiler, there is a range of different applications and features. 2. Gas boiler room, whether it takes 24 hours on duty? In addition, two tons of gas boiler, its price is mainly related to what?