10 ton Supplier Commercial hot water boiler Maldives

Daily maintenance and routine maintenance and maintenance of knowledge knowledge maintenance electric steam boiler electric steam boiler 1, the boiler water must be treated to soften water standards-compliant. Repairs, boiler maintenance, you must cut off the power supply must be relief. 2, boiler blowdown must be every day, to ensure clean water in the boiler. 3, always check the transmission line, to the pump, the control box member key health, safety valves and pressure switches, time to find abnormal reasons, timely maintenance. 4, water table should always be kept clean, wash once a day, so ensure to see the water level, moving relief valve once a day, to prevent rusting failure. 5, boiler stop running for a long time, should cut off the power while the boiler, the water inside the pipes put the net to prevent frost damage, rusting. 6, a sudden power outage, the power should be turned off, the inlet valve. 7, by listening, smell, see, touch control box to do normal maintenance work. Such as abnormal phenomenon should immediately cut off the power timely maintenance. 8, the periodic electric heating tube fastening nut and the screw flange connection. 9, electric heating oven in the vapor easy to scale. If there is no softening equipment steam boiler, electric heating is recommended once a month detached, to remove the scale. If treatment equipment should disassemble the tube was heated at six months or a descaling. Note again the electric heating tube connection recovery, good fastening screws on the flange, the fastening screws should be fastened symmetrically repeatedly tightened in order to avoid water leakage occurs. 10, when the boiler is stopped, the power should be cut off, the control box is opened, check all the electrical connections of the nut member, looseness should be tightened to prevent poor contact and electrical wires burning member. 11, every six months or a year the boiler must be an internal cleaning, cleaning work to ensure that the boiler efficiency and service life.

The main use of 10 ton supplier commercial hot water boiler maldives resistance, the reason for the lack of air volume heating and hot water boiler in the bath, like hotels, baths can be used in these industries, but often there will be great resistance in the system used in the process insufficient air flow for the phenomenon, the following'll tell you about the big boilers force, the reason for the lack of air volume: First, the capacity is not the same main steam pressure regulator 1 performance, improved system for each boiler has its own master steam pressure regulator, the regulator and the proportional regulator, proportional band may be set according to their size with a load capacity of the boiler, there is no influence on each other. 2, the fuel conditioning subsystem original system is no difference in the main circuit system, fuel system improved conditioning subsystem for the main circuit with a heterodyne system, the main pipe when pressure is not rated range, by varying the pressure to each boiler setting, to maintain the pressure main pipe. 3, main pipe according to the original system pressure change is adjusted by the main steam pressure of the boiler load assignment, the improved system, each carried by boiler load changes depending on the size of each of the main regulator of the proportional band. Second, the resistance, the air volume is insufficient for reasons: 1, particle size of the fuel mixture, lump coal occupy voids, is pressed into the compact when the shutter grate, poor ventilation, one lump coal fuel can not penetrate to slagging still fire, the burning member slag, slag 2 high residual carbon content, coal coal leakage serious. 3, a large resistance: the fan load increases, high power consumption, low furnace temperature difference and not coal combustion, the furnace temperature is low, and sometimes fire, a large number of ash and unburned matter economizer and the air preheater clogging the pressure in the combustion furnace. Hot water boiler or other heat utilizing thermal energy released by the combustion of the fuel, the water is heated to a nominal temperature of the thermal device. So when found in large power systems leads to the lack of supply of wind, we should be careful analysis, to find the answer, recovery systems.

Hefei Limin Pharmaceutical Co., Ltd. Nanjing Military Region, formerly the backbone of pharmaceutical companies, the main drug is slowly swallow rather teabag, relying on advanced R & D platform to carry out contract manufacturing, OEM OEM and other business cooperation. China's environmental protection development trend began to take shape, many environmental policies have been put forward for a positive response to the national environmental policy, Limin Pharmaceutical decided to introduce a gas station steam boilers. After an investigation of the boiler market, Limin Pharmaceutical fast boiler is strong comprehensive strength and wealth of experience working for many years in the pharmaceutical industry to attract, party fast according to the actual needs of customers for its recommendation of one of Taiwan 4 tons of steam condensate gas-fired steam boiler (WNS4-1.25-YQ).

After the steam boiler periodically clear the importance of the steam boiler scale use for a long time, pay attention to the latter part of the maintenance work, be sure to regularly clean up the steam boiler scale, to ensure the normal operation of the boiler. Here to talk about the harm steam boiler scale points: First, the thermal conductivity of the scale than the steam boiler plate tens to hundreds of decimal places, after the heating surface fouling causes deterioration of heat exchange, increased smoke temperature, decreasing the thermal efficiency of the boiler, waste of fuel. Second, affect the safe operation. Boiler normal operation, after metal transfers heat to quickly heat the water pot, both the temperature difference of about 30 ℃ -100 ℃. When there is scale, metallic heat transfer blocked, and thus a sharp increase in temperature, strength is significantly decreased, resulting in deformation of the pressure receiving member overheating, explosion or even bulge. The third is to destroy the water cycle. Junction raw scale steam boiler, heat is not good because the reduced evaporation, reduced boiler output. When the inner tube fouling, flow cross sectional area is reduced, increasing the flow resistance of the water cycle, the tube will be completely blocked severe, disruption of normal circulation, causing tube rupture. Fourth shorten the life of the boiler. Heating surface attached to the steam boiler scale in particular heating surface is difficult to eliminate. When cleaning requires frequent shutdown to clean, increased maintenance costs, often using mechanical and chemical methods of heating surface cleaning will damage and shorten the life of the steam boiler.