6th gas steam boiler

Shandong Zhaoyuan Mining Group Co., Ltd. is a large state-owned local asset management companies, gold mining dressing and smelting for leading industries, operates in the area of ​​tourism, services, precious metals, real estate, eco-agriculture, with total assets of 10.2 billion yuan, Shanghai gold Exchange is an international provider of standard gold bullion. July 2017, Shandong Mining Group and fast boiler steam signed a 0.5-ton electric heating 6th steam boiler which mainly produce steam for metallurgical mineral processing and other manufacturing processes, energy defeating small, strong ability to supply steam .

Scale thermal conductivity gas 6th steam boiler is only one out of steel gas steam boiler efficient and environmentally friendly use of non-corrosive cleaning agent in the cleaning process of cleaning the boiler. This will cause the device to the metal tube is exposed to the primary colors, and reduce the effects of biological fouling algae sludge. After ignition gas steam boiler, furnace and to observe the temperature of main steam. Main steam pressure rises, the boiler flue gas temperature significantly higher ignition. If the temperature does not rise, you should immediately to the scene to check the oil gun fire. Scale thermal conductivity gas steam boiler is only one-tenth of steel. When it is scale on the heated surface, which will hinder the heat transfer effect. To maintain the boiler output constant during use, the need to increase the temperature of the combustion side. Gas-fired steam boiler furnace exit temperature rise, increasing the loss of gas steam boiler scale on the device can effectively reduce the water wall heat transfer, the temperature of the water is likely to lead to an increase in the wall, resulting in a wall of water burst. When the gas steam boiler, the furnace will be a series of chemical and physical reactions. During use, it will be effective to form a dense and hard scale on the heating surface, which will lead directly to heat exchange. Due to the scale and efficiency while reducing corrosion can lead to heat gas boiler absorption.

Process safety valve check valve gas 6th steam boiler is one of the three safety accessories gas steam boiler, when the boiler pressure is too high, the pressure relief valve will automatically exhaust, gas steam boiler is the important safety equipment . The case of a new installation, overhaul, lack of consumer safety valve shutdown and restart more than three consecutive months, have had to re-check safety valve, safety valve to ensure accurate and reliable by the company safety officer, boiler technician, run operators, maintenance personnel together with the completion of the adjustment. Valve adjustment procedure is as follows: 1, the steam boiler when the gas vapor pressure close to the operating pressure of the safety valve, and retest check valve to the air motor exhaust, drainage accident flexibility and reliability of the electric valve, and the panel reinspection situ pressure gauge, the water level of accuracy, such as failure, not allowed to heat the school. 2, ready to call and check the quality of communication tools, a signal indicating whether the good. 3, adjust the safety valves, boiler pressure should be kept stable, pay attention to monitoring gas steam boiler drum level, and maintain normal. 4, steam boiler safety valve to adjust the pressure gauge in place of instructions shall prevail. If necessary using 0.4 or more for the accuracy of the gauge. 5, adjust the safety valve should be carried out only by descending. It should checksum gas steam boiler tuning high pressure safety valve, after the school seizure of the entire set of low pressure relief valve. 6, the following should be in the 0.3MPa, the movement preventing measures must do a good job of setting relatively low pressure steam boiler safety valve safety valve before adjusting. 7, by combustion, and exhaust steam adjust the degree of opening to the air slowly and smoothly up to the required setting pressure. 8, when the gas pressure steam boiler safety valve set pressure to rise if action is normal, then the action and reseating pressure values ​​recorded. If action is not correct or not action should be immediately opened to the air exhaust valve, while the combustion boiler weakened, stop boost, and buck 0.3MPa or less, re-adjust the boiler technician as required by maintenance personnel, until the compliance date. (Lead or lag 0.05MPa action is normal). 9, after the completion valve to adjust gas steam boiler, boiler 0.3MPa or less down to the lifting device and can be installed and fastened to the protective cover, a braking measure required under check valve removal, then Articles 7, 8 verify until all required safety valve calibration check is completed. 10, the safety valve to adjust the gas boiler, check the results recorded in the "safety valve to adjust the recording Visa" within the participants should verify the signatures and Internet safety valve input to the corresponding data in the ledger. During operation gas steam boiler, not only to regularly check on the safety valve, at the same time, we must regularly monitor boiler inspection to ensure that the boiler fully meet the safety requirements!

Maintenance of the boiler plant food during the maintenance shutdown has deactivated which is to prevent boiler corrosion. Since boiler shutdown, a large boiler humidity, poor ventilation, if long-term in a wet state, oxygen in the air with the metal heating surface of the wet complete contact, the inner surface layer of brown rust generated; in addition, often the heat receiving surface of the gas side accumulating ash particles during operation, after the shutdown in the humid environment, will cause corrosion of metals. In the boiler shutdown process, the main reason is the presence of moisture and corrosion of metal surfaces of the air. Thus, as long as the metal surface or a metal surface with dry air (oxygen) isolation, can effectively prevent corrosion. The length of the parking time, there are packing, Paul dry, wet security, ventilation PROTECTION. 1, pressure maintenance Pressure maintenance is suitable for up to one week shutdown of the boiler. The residue pot pressure 0.05 ~ 0.1MPa, temperature slightly above 100 ℃. Boiler pressure and temperature to maintain regular methods using steam heating the water adjacent to the boiler, a heating boiler or intermittently. 2. Dry Dry care maintenance is a method to protect the desiccant into the pot and in the furnace. Its purpose is to keep no water jug. The utility model is suitable for long-term or seasonal shutdown boiler heating boiler. Open manholes and hand holes, the header and the drum-dried. When wet boiler room, with appropriate use of the furnace heat or light burning wood, so that the furnace, the furnace wall flue drying. After drying the boiler is cooled, the opening and tray formulated desiccant tube is placed in the pot, and a collecting box grate, then tightly closes the inlet aperture, and a valve connected to the hand hole to prevent air from entering. For some Mifengbuyan valves, plug board should be increased.