delicate processing gas hot water atmospheric pressure boiler supplier

3.Heavy industrial applications burning gas, oil, refinery gas, hydrogen and off-gas fuels.

4.Higher thermal efficiency levels are possible,Less tolerance for water quality calls for water treatment plant.

5.With totally automatic burner and full set of safety protection device, thus automatic safety operation can be guaranteed.

6.The heat exchange surface area of the boiler and the space for water and steam are large enough to make sure the boiler parameters are stable.

7.The rear section of such boiler is equipped with flue gas condensing and recovery device which can effectively control exhaust gas temperature so that to improve boiler thermal efficiency.

8.Adopts high heat resistance material as adiabatic layer which brings a good thermal insulation property; the outer shell of the boiler adopts pressed guard board which makes the boiler looks delicate.

9.Adopts packaged structure; the whole boiler is fixed on the steel base with strong rigidity. Such structure provides convenience for installation and transportation.

Henan gas delicate processing hot water atmospheric pressure boiler supplier shutdown operation process: 1, electric control box Press Henan gas boiler "shutdown" button; 2, burner servomotor return to the initial position, the throttle valve is fully closed and gas; 3, solenoid valve and gas regulating safety valve is closed, the blower stops rotating; 4, after determining the water temperature is below 50 ℃, stop the circulating pump. 5, closing the manual gas valve; 6, close the water supply valve and return valve; 7, check the gas lines, water lines, air leak valve for leaks; 8, down air switch; 9, when the long-term without cutting Henan power gas-fired boiler. For more information Henan gas boiler: On the protection of Henan gas boiler - safety valve (a)

Why gas steam delicate processing hot water atmospheric pressure boiler supplier energy saving may be why gas steam boiler energy saving gas steam boiler design pressure should be slightly higher than the high work pressure, and not less than safety valve opening pressure. Design pressure gas furnace using 1.2 to 1.5 times the working pressure; liquid pressure furnace design should take pressure of 1.05 to 1.2 times; Liquid furnace gas and steam outlet pressure differential should be greater than 0.15MPa (1.5kgf / cm2). Temperature gas steam boiler import and export, from the design of both economic and security point of view, to design gas-steam to run a suitable temperature difference in the system, this temperature difference should be less than 30 ℃. Gas steam boiler is a closed loop, the return oil temperature and oil temperature only a 20-30, 20-30 words, only heating the temperature difference can reach temperature gas steam boiler. The steam boiler is added to cold water, the cold water is heated into steam to heat heating device, steam becomes condensed water discharged 60-70 degrees. Therefore, the role of energy saving functions!

Our hospital requirements for environmental protection, health and safety in these areas is very high, for a wide variety of market delicate processing hot water atmospheric pressure boiler supplier is also very headache and confusion, there fast boiler solve the above problem, the boiler set clean environment to provide for our hospitals and efficient operation in one, coincides with the philosophy of our hospital. --customer feedback